Terbium radioisotopes (149Tb, 152Tb, 155Tb, 161Tb) offer a unique class of radionuclides which encompass all four medicinally relevant nuclear decay modalities (α, β+, γ, β−/e−), and show high potential for the development of element-matched theranostic radiopharmaceuticals. The goal of this study was to design, synthesise, and evaluate the suitability of crown-TATE as a new peptide-conjugate for radiolabelling of [155Tb]Tb3+ and [161Tb]Tb3+, and to assess the imaging and pharmacokinetic properties of each radiotracer in tumour-bearing mice. [155Tb]Tb-crown-TATE and [161Tb]Tb-crown-TATE were prepared efficiently under mild conditions, and exhibited excellent stability in human serum (>99.5% RCP over 7 days). Longitudinal SPECT/CT images were acquired for 155Tb- and 161Tb- labelled crown-TATE in male NRG mice bearing AR42J tumours. The radiotracers, [155Tb]Tb-crown-TATE and [161Tb]Tb-crown-TATE, showed high tumour targeting (32.6 and 30.0 %ID/g, respectively) and minimal retention in non-target organs at 2.5 h post-administration. Biodistribution studies confirmed the SPECT/CT results, showing high tumour uptake (38.7 ± 8.0 %ID/g and 38.5 ± 3.5 %ID/g, respectively) and favourable tumour-to-background ratios. Blocking studies further confirmed SSTR2-specific tumour accumulation. Overall, these findings suggest that crown-TATE has great potential for element-matched molecular imaging and radionuclide therapy using 155Tb and 161Tb.
Objective: The development of alpha-emitting radiopharmaceuticals using 225Ac (t½=9.92 d) benefits from the quantitative determination of its biodistribution and is not always easy to directly measure. An element-equivalent matched-pair would allow for more accurate biodistribution and dosimetry estimates. 226Ac (t½=29.4 h) is a candidate isotope for in vivo imaging of preclinical 225Ac radiopharmaceuticals, given its 158 keV and 230 keV gamma emissions making it suitable for quantitative SPECT imaging. This work aimed to conduct a performance assessment for 226Ac imaging and presents the first-ever 226Ac SPECT images. Approach: To establish imaging performance with regards to contrast and noise, image quality phantoms were scanned using a microSPECT/CT system. To assess the resolution, a hot rod phantom with cylindrical rods with diameters between 0.85 – 1.70 mm was additionally imaged. Two collimators were evaluated: a high-energy ultra-high resolution (HEUHR) collimator and an extra ultra-high sensitivity (UHS) collimator. Images were reconstructed from two distinct photopeaks at 158 keV and 230 keV. Main results: The HEUHR SPECT image measurements of high activity concentration regions were consistent with values determined independently via gamma spectroscopy, within 9% error. The lower energy 158 keV photopeak images demonstrated slightly better contrast recovery. In the resolution phantom, the UHS collimator only resolved rods ≥1.30 mm and ≥1.50 mm for the 158 keV and 230 keV photopeaks, respectively, while the HEUHR collimator clearly resolved all rods, with resolution <0.85 mm. Significance: Overall, the feasibility of preclinical imaging with 226Ac was demonstrated with quantitative SPECT imaging achieved for both its 158 keV and 230 keV photopeaks. The HEUHR collimator is recommended for imaging 226Ac activity distributions in small animals due to its resolution <0.85 mm. Future work will explore the feasibility of using 226Ac both as an element-equivalent isotope for 225Ac radiopharmaceuticals, or as a standalone therapeutic isotope.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.