With aggregometry, increased platelet activity has been reported in Cavalier King Charles Spaniels (CKCS) without mitral regurgitation (MR). In contrast, dogs with MR have been found to have decreased platelet activity. The purpose of this study was to test an easy bedside test of platelet function (the Platelet Function Analyzer [PFA-100]) to see if it could detect an increase in platelet activity in CKCS without MR and a decrease in platelet activity in CKCS with MR. This study included 101 clinically healthy dogs > 1 year of age: 15 control dogs of different breeds and 86 CKCS. None of the dogs received medication or had a history of bleeding. The PFA-100 evaluates platelet function in anticoagulated whole blood under high shear stress. Results are given as closure times (CT): the time it takes before a platelet plug occludes a hole in a membrane coated by agonists. The CT with collagen and adenosine-diphosphate as agonists was similar in control dogs (median 62 seconds; interquartile interval 55-66 seconds) and CKCS with no or minimal MR (55; 52-64 seconds). The CT was higher in CKCS with mild MR (regurgitant jet occupying 15-50% of the left atrial area) (75; 60-84 seconds; P = .0007) and in CKCS with moderate to severe MR (jet > 50%) (87: 66-102 seconds; P < .0001). CKCS with mild, moderate, and severe, clinically inapparent MR have decreased platelet function. The previous finding of increased platelet reactivity in nonthrombocytopenic CKCS without MR could not be reproduced with the PFA-100 device.
With aggregometry, increased platelet activity has been reported in Cavalier King Charles Spaniels (CKCS) without mitral regurgitation (MR). In contrast, dogs with MR have been found to have decreased platelet activity. The purpose of this study was to test an easy bedside test of platelet function (the Platelet Function Analyzer [PFA-100]) to see if it could detect an increase in platelet activity in CKCS without MR and a decrease in platelet activity in CKCS with MR. This study included 101 clinically healthy dogs > 1 year of age: 15 control dogs of different breeds and 86 CKCS. None of the dogs received medication or had a history of bleeding. The PFA-100 evaluates platelet function in anticoagulated whole blood under high shear stress. Results are given as closure times (CT): the time it takes before a platelet plug occludes a hole in a membrane coated by agonists. The CT with collagen and adenosine-diphosphate as agonists was similar in control dogs (median 62 seconds; interquartile interval 55-66 seconds) and CKCS with no or minimal MR (55; 52-64 seconds). The CT was higher in CKCS with mild MR (regurgitant jet occupying 15-50% of the left atrial area) (75; 60-84 seconds; P = .0007) and in CKCS with moderate to severe MR (jet > 50%) (87: 66-102 seconds; P < .0001). CKCS with mild, moderate, and severe, clinically inapparent MR have decreased platelet function. The previous finding of increased platelet reactivity in nonthrombocytopenic CKCS without MR could not be reproduced with the PFA-100 device.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.