BackgroundIndocyanine green (ICG) fluorescence imaging has been a new surgical navigation technique for gastric cancer. However, its clinical value should still be evaluated further. In this meta-analysis, we investigated the safety and efficacy of ICG near-infrared fluorescent imaging-guided lymph nodes (LNs) dissection during radical gastrectomy.MethodsStudies comparing ICG fluorescence imaging with standard care in patients with gastric cancer were systematically searched from PubMed, Embase, Web of Science, and Cochrane Library through August 2021. The current meta-analysis was performed according to the preferred reporting items for systematic review and meta-analysis guidelines. A pooled analysis was performed for the available data regarding the number of LNs dissection, the number of metastatic LNs dissection, other operative outcomes, and postoperative complications. R software version 4.2.0 and Stata 16.0 software were used for the present meta-analysis.ResultsThis analysis included 12 studies with a total of 1365 gastric cancer patients (569 in the ICG group and 796 in the non-ICG group). The number of retrieved LNs in the ICG group was significantly higher (weighted mean difference [WMD]=7.67, 95% confidence intervals [CI]: 4.73 to 10.62, P<0.05) compared to the non-ICG group with moderate heterogeneity (P<0.001, I2 = 70%). The number of metastatic LNs, operative time, and postoperative complications were all comparable and without significant heterogeneity. Additionally, ICG near-infrared fluorescent imaging was associated with reduced intraoperative blood loss (WMD=-10.28, 95% CI: -15.22 to -5.35, P<0.05) with low heterogeneity (P=0.07, I2 = 43%).ConclusionsICG near-infrared fluorescent imaging-guided lymphadenectomy was considered to be safe and effective in gastrectomy. ICG was used to increase the number of LNs harvested while reducing intraoperative blood loss without increasing operative time or postoperative complications.Systematic Review Registrationhttps://www.crd.york.ac.uk/PROSPERO/, identifier CRD42021291863.
Purpose
It is difficult to maintain sufficient tension throughout laparoscopic anterior resection with total mesorectal excision, which causes a decline in surgical quality. We used a soft, inexpensive gauze pad band pulling the rectal tube to analyze the effect of surgery.
Methods
A gauze pad band was positioned at the proximal of the tumor, followed by fastening the rectal tube and ligating the rectum. 233 patients undergoing laparoscopic anterior resection for mid to low rectal cancer were enrolled between January 2018 and December 2020. After propensity score matching, 63 cases were selected in gauze pad band group and 126 cases were selected in traditional group. The two groups were compared in preoperative, intraoperative, and pathological characteristics.
Results
Compared to traditional group, the median operation duration (203 min vs. 233 min, p < 0.001) and the median intraoperative bleeding (48 ml vs. 67 ml, p < 0.001) were lesser in gauze pad band group. A higher percentage of one cartridge transection of rectum (36/63 vs. 51/126, p = 0.030), shorter length of cartridges used (6.88 ± 1.27 cm vs. 7.28 ± 1.25 cm, p = 0.040), and longer distal resection margin (2.74 ± 0.76 cm vs. 2.16 + 0.68 cm, p < 0.001) were found in the gauze pad band group. The completeness of total mesorectal excision (61/63 vs. 109/126, p = 0.022), harvested lymph nodes (19 vs. 17, p < 0.001) and positive lymph nodes (1 vs. 0, p = 0.046) were higher in gauze pad band group.
Conclusion
Ligation of the rectum with a gauze pad band allows for a reduction in operative time and intraoperative bleeding while increasing the rate of one cartridge transection. It also protected the quality of total mesorectal excision and membrane anatomy.
Trial registration: Not applicable.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.