Hypoxia during haemodialysis, mainly acetate, has been reported several times. In our study we have monitored oxygen status during 258 bicarbonate haemodialyses. A significant drop below 80 mmHg in mean oxygen tension occurred. Mean oxygen saturation reflected this drop but did not reach levels below 90%. The mean oxygen concentration was on the whole critical low, though slightly increasing during each haemodialysis session due to ultrafiltration.
It is concluded that both hypoxia and hypoxaemia do occur during bicarbonate haemodialysis. To a group of patients generally having limited cardiac reserves, a poor oxygen status is a potentially serious complication to haemodialysis. Monitoring oxygen status is thus advisable.
In 69 patients on chronic haemodialysis, blood sampled randomly during dialysis was analyzed for carboxyhaemoglobin (COHb). The median value was 1.40% (range 0.9-2.3) in non-smoking patients and (1.4-7.5) in smokers. In non-smokers treated with erythropoietin (EPO) correlation was found between COHb and the weekly EPO dose (r = 0.57, p = 0.007). In smoking patients not given EPO, the COHb correlated well with the number of cigarettes smoked (r = 0.84, p = 0.003). The COHb values did not correlate to the haemoglobin values. It is concluded that COHb levels in uraemic non-smokers are elevated because of increased endogenous CO production from the enhanced erythrocyte turnover. As even low COHb levels may negatively influence the oxygen status of the uraemic patient, the addition of exogenous CO from cigarette smoking should be avoided.
Background: In patients with arteriovenous fistulas, assessment of pH and oxygen status during hemodialysis (HD) using the extracorporeal dialysis arterial blood line is widely used both in daily routine and in most studies investigating hypoxia during HD. We designed this study to evaluate whether results of blood gas samples drawn from the extracorporeal arterial line were clinically acceptable in assessing oxygen status. Methods: We compared samples drawn from the extracorporeal arterial line with conventionally arterial punctures during 18 routine HD sessions. The samples were drawn simultaneously and analyzed immediately for blood gases, pH and hemoximetry values. Results: No significant difference was found between the values from the radial artery and the extracorporeal arterial blood line except for FMetHb. Conclusion: Thus, obtaining samples from the extracorporeal dialysis arterial blood line to evaluate the parameters of the oxygen status (pH, pO2, pCO2, ctHb, sO2, FCOHb and ctO2) during routine HD is a clinically convenient and accurate sampling approach.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.