Many postmenopausal women have vitamin D and calcium deficiency. Therefore, vitamin D and calcium supplementation is recommended for all patients with osteopenia and osteoporosis. We used an experimental rat model to test the hypothesis that induction of osteoporosis is more efficiently achieved in peripheral bone through combining ovariectomy with a unique multi-deficiencies diet (vitamin D depletion and deficient calcium, vitamin K and phosphorus). 14-week-old Sprague-Dawley rats served as controls to examine the initial bone status. 11 rats were bilaterally ovariectomized (OVX) and fed with multi-deficiencies diet. Three months later the treated group and the Sham group (n = 8) were euthanized. Bone biomechanical competence of the diaphyseal bone was examined on both, tibia and femur. Image analysis was performed on tibia via µCT, and on femur via histological analysis. Lower torsional stiffness indicated inferior mechanical competence of the tibia in 3 month OVX+Diet. Proximal metaphyseal region of the tibia showed a diminished bone tissue portion to total tissue in the µCT despite the increased total area as evaluated in both µCT and histology. Cortical bone showed higher porosity and smaller cross sectional thickness of the tibial diaphysis in the OVX+Diet rats. A lower ALP positive area and elevated serum level of RANKL exhibited the unbalanced cellular interaction in bone remodeling in the OVX+Diet rat after 3 month of treatment. Interestingly, more adipose tissue area in bone marrow indicated an effect of bone loss similar to that observed in osteoporotic patients. Nonetheless, the presence of osteoid and elevated serum level of PTH, BGP and Opn suggest the development of osteomalacia rather than an osteoporosis. As the treatment and fracture management of both osteoporotic and osteomalacia patients are clinically overlapping, this study provides a preclinical animal model to be utilized in local supplementation of minerals, drugs and growth factors in future fracture healing studies.
Background The COVID-19 pandemic has not only changed the private lives of millions of people but has significantly affected the collaboration of medical specialists throughout health care systems worldwide. Hospitals are making changes to their regular operations to slow the spread of SARS-CoV-2 while ensuring the treatment of emergency patients. These substantial changes affect the typical work setting of clinicians and require the implementation of organizational arrangements. Objective In this study, we aim to increase our understanding of how digital transformation drives virtual collaboration among clinicians in hospitals in times of crisis, such as the COVID-19 pandemic. Methods We present the lessons learned from an exploratory case study in which we observed the introduction of an information technology (IT) system for enhancing collaboration among clinicians in a German hospital. The results are based on 16 semistructured interviews with physicians from various departments and disciplines; the interviews were generalized to better understand and interpret the meaning of the statements. Results Three key lessons and recommendations explain how digital transformation ensures goal-driven collaboration among clinicians. First, we found that implementing a disruptive change requires alignment of the mindsets of the stakeholders. Second, IT-enabled collaboration presupposes behavioral rules that must be followed. Third, transforming antiquated processes demands a suitable technological infrastructure. Conclusions Digital transformation is being driven by the COVID-19 pandemic. However, the rapid introduction of IT-enabled collaboration reveals grievances concerning the digital dissemination of medical information along the patient treatment path. To avoid being caught unprepared by future crises, digital transformation must be further driven to ensure collaboration, and the diagnostic and therapeutic process must be opened to disruptive strategies.
Cranioplasties show overall high complication rates of up to 45.3%. Risk factors potentially associated with the occurrence of postoperative complications are frequently discussed in existing research. The present study examines the positioning of 39 patient-specific implants (PSI) made from polyetheretherketone (PEEK) and retrospectively investigates the relationship between the fitting accuracy and incidence of postoperative complications. To analyze the fitting accuracy of the implants pre- and post-operatively, STL files were created and superimposed in a 3D coordinate system, and the deviations were graphically displayed and evaluated along with the postoperative complications. On average, 95.17% (SD = 9.42) of the measurements between planned and surgically achieved implant position were within the defined tolerance range. In cases with lower accordance, an increased occurrence of complications could not be demonstrated. The overall postoperative complication rate was 64.1%. The fitting of the PEEK-PSI was highly satisfactory. There were predominantly minor deviations of the achieved compared to the planned implant positions; however, estimations were within the defined tolerance range. Despite the overall high accuracy of fitting, a considerable complication rate was found. To optimize the surgical outcome, the focus should instead be directed towards the investigation of other risk factors.
Contemporary advances in technology have allowed the transfer of knowledge from industrial laser melting systems to surgery; such an approach could increase the degree of accuracy in orbital restoration. The aim of this study was to examine the accuracy of selective laser melted PSIs (patient-specific implants) and navigation in primary orbital reconstruction. Ninety-six patients with orbital fractures were included in this study. Planned vs. achieved orbital volumes (a) and angles (b) were compared to the unaffected side (n = 96). The analysis included the overlay of post-treatment on planned images (iPlan 3.0.5, Brainlab®, Feldkirchen, Germany). The mean difference in orbital volume between the digitally planned orbit and the postoperative orbit was 29.16 cm3 (SD 3.54, presurgical) to 28.33 cm3 (SD 3.64, postsurgical, t = 5.00, df = 95.00; p < 0.001), resulting in a mean volume difference (planned vs. postop) of less than 1 cm3. A 3D analysis of the color mapping showed minor deviations compared to the mirrored unaffected side. The results suggested that primary reconstruction in complex orbital wall fractures can be routinely achieved with a high degree of accuracy by using selective laser melted orbital PSIs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.