AimsExcessive bleeding impairs outcome after coronary artery bypass grafting (CABG). Current guidelines recommend withdrawal of clopidogrel and ticagrelor 5 days (120 h) before elective surgery. Shorter discontinuation would reduce the risk of thrombotic events and save hospital resources, but may increase the risk of bleeding. We investigated whether a shorter discontinuation time before surgery increased the incidence of CABG-related major bleeding complications and compared ticagrelor- and clopidogrel-treated patients.Methods and resultsAll acute coronary syndrome patients in Sweden on dual antiplatelet therapy with aspirin and ticagrelor (n = 1266) or clopidogrel (n = 978) who underwent CABG during 2012–13 were included in a retrospective observational study. The incidence of major bleeding complications according to the Bleeding Academic Research Consortium-CABG definition was 38 and 31%, respectively, when ticagrelor/clopidogrel was discontinued <24 h before surgery. Within the ticagrelor group, there was no significant difference between discontinuation 72–120 or >120 h before surgery [odds ratio (OR) 0.93 (95% confidence interval, CI, 0.53–1.64), P = 0.80]. In contrast, clopidogrel-treated patients had a higher incidence when discontinued 72–120 vs. >120 h before surgery (OR 1.71 (95% CI 1.04–2.79), P = 0.033). The overall incidence of major bleeding complications was lower with ticagrelor [12.9 vs. 17.6%, adjusted OR 0.72 (95% CI 0.56–0.92), P = 0.012].ConclusionThe incidence of CABG-related major bleeding was high when ticagrelor/clopidogrel was discontinued <24 h before surgery. Discontinuation 3 days before surgery, as opposed to 5 days, did not increase the incidence of major bleeding complications with ticagrelor, but increased the risk with clopidogrel. The overall risk of major CABG-related bleeding complications was lower with ticagrelor than with clopidogrel.
Aims Transcatheter aortic valve implantation (TAVI), now a common procedure to treat high-risk patients with severe aortic stenosis, has rapidly been expanding into younger and lower-risk populations, creating a need to better understand long-term outcome after TAVI. The aim of the present investigation was to determine the incidence, risk factors for, clinical presentation of, and outcome after prosthetic valve endocarditis (PVE) in patients treated with TAVI in a nationwide study. Methods and results Three registries were used: a national TAVI registry, a national diagnosis registry, and a national infective endocarditis registry. Combining these registries made it possible to perform a nationwide, all-comers study with independent and validated reporting of PVE in 4336 patients between 2008 and mid-2018. The risk for PVE after TAVI was 1.4% (95% confidence interval 1.0–1.8%) the first year and 0.8% (0.6–1.1%) per year thereafter. One-year survival after PVE diagnosis was 58% (49–68%), and 5-year survival was 29% (17–41%). Body surface area, estimated glomerular filtration rate <30 mL/min/1.73 m2, critical pre-operative state, mean pre-procedural valve gradient, amount of contrast dye used, transapical access, and atrial fibrillation were identified as independent risk factors for PVE. Staphylococcus aureus was more common in early (<1 year) PVE. Infection with S. aureus, root abscess, late PVE, and non-community acquisition was associated with higher 6-month mortality. Conclusion The incidence of PVE was similar to that of surgical bioprostheses. Compromised renal function was a strong risk factor for developing PVE. In the context of PVE, TAVI seems to be a safe option for patients. Clinical Trial Registration NCT03768180 (http://clinicaltrials.gov/).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.