IntroductionPrediction of massive transfusion (MT) among trauma patients is difficult in the early phase of trauma management. Whole-blood thromboelastometry (ROTEM®) tests provide immediate information about the coagulation status of acute bleeding trauma patients. We investigated their value for early prediction of MT.MethodsThis retrospective study included patients admitted to the AUVA Trauma Centre, Salzburg, Austria, with an injury severity score ≥16, from whom blood samples were taken immediately upon admission to the emergency room (ER). ROTEM® analyses (extrinsically-activated test with tissue factor (EXTEM), intrinsically-activated test using ellagic acid (INTEM) and fibrin-based extrinsically activated test with tissue factor and the platelet inhibitor cytochalasin D (FIBTEM) tests) were performed. We divided patients into two groups: massive transfusion (MT, those who received ≥10 units red blood cell concentrate within 24 hours of admission) and non-MT (those who received 0 to 9 units).ResultsOf 323 patients included in this study (78.9% male; median age 44 years), 78 were included in the MT group and 245 in the non-MT group. The median injury severity score upon admission to the ER was significantly higher in the MT group than in the non-MT group (42 vs 27, P < 0.0001). EXTEM and INTEM clotting time and clot formation time were significantly prolonged and maximum clot firmness (MCF) was significantly lower in the MT group versus the non-MT group (P < 0.0001 for all comparisons). Of patients admitted with FIBTEM MCF 0 to 3 mm, 85% received MT. The best predictive values for MT were provided by hemoglobin and Quick value (area under receiver operating curve: 0.87 for both parameters). Similarly high predictive values were observed for FIBTEM MCF (0.84) and FIBTEM A10 (clot amplitude at 10 minutes; 0.83).ConclusionsFIBTEM A10 and FIBTEM MCF provided similar predictive values for massive transfusion in trauma patients to the most predictive laboratory parameters. Prospective studies are needed to confirm these findings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.