Purpose
Different fixation methods are used for treatment of unstable lateral clavicle fractures (LCF). Definitive consensus and guidelines for the surgical fixation of LCF have not been established. The aim of this study was to compare patient-reported functional outcome after open reduction and internal fixation with the clavicle hook plate (CHP) and the superior clavicle plate with lateral extension (SCPLE).
Methods
A dual-center retrospective cohort study was performed. All patients operatively treated for unstable Neer type II and type V LCF between 2011 and 2016, with the CHP (n = 23) or SCPLE (n = 53), were eligible for inclusion. The primary outcome was the QuickDASH score. Secondary outcomes were the numerical rating scale (NRS) pain score, complications, and implant removal.
Results
A total of 67 patients (88%) were available for the final follow-up. There was a significant difference in bicortical lateral fragment size, 15 mm (± 4, range 6–21) in the CPH group compared to 20 mm (± 8, range 8–43) in the SCPLE group (p ≤ 0.001). There was no significant difference in median QuickDASH score (CHP; 0.00 [IQR 0.0–0.0], SCPLE; 0.00 [IQR 0.0–4.5]; p = 0.073) or other functional outcome scores (NRS at rest; p = 0.373, NRS during activity; p = 0.559). There was no significant difference in median QuickDASH score or other functional outcome scores between Neer type II and type V fractures. There was no significant difference in complication rate, CHP 11% and SCPLE 8% (relative risk 1.26; [95% CI 0.25–6.33; p = 0.777]). The implant removal rate was 100% in the CHP group compared to 42% in the SCPLE group (relative risk 2.40; [95% CI 1.72–3.35; p ≤ 0.001]).
Conclusion
Both the CHP and SCPLE are effective fixation methods for the treatment of unstable LCF, resulting in excellent patient-reported functional outcome and similar complication rates. SCPLE fixation is an effective fixation method for the treatment of both Neer type II and type V LCF. The SCPLE has a lower implant removal rate. Therefore, if technically feasible, we recommend SCPLE fixation for the treatment of unstable LCF.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.