Supplies of fresh water in everyday life has increased, but the smaller the potential sources of water so we need to think of alternative uses of water for concrete construction work. This study aims to compare the compressive strength of concrete using sea water and fresh water with water cement ratio of 0.37. An experimental research was conducted by making specimens of concrete cylinder with a diameter of 150 mm and height of 300 mm. The study used specimens of concrete using sea water and fresh water. There were 32 specimens for each kind of concrete. The treatment of each specimen used sea water and fresh water in accordance with the type of mixing water. The immersion periods were 1, 3, 7 and 28 days. Mechanical testing of concrete was conducted by testing the compressive strength and elasticity, while the testing of concrete microstructure was conducted by using X-Ray Diffraction (XRD) and Scan Electron Microscopy (SEM). The results revealed that in the 28-day immersion period. The compressive strength values of the sea water concrete and fresh water concrete were 44.88 MPa and 44.03 Mpa respectively. The difference of compressive strength in the two types of concrete was not significant. The result of microstructure test in the 28-day period revealed that in the sea water concrete, there was a formation of Friedel’s salt (3CaO.Al2O3.CaCl2.10H2O) of 7.71%, tobemorite (3CaO.2SiO2.3H2O) of 58.66% and calcium hydroxide (Ca(OH)2) of 6.18%. In the fresh water concrete, there was a formation of tobermorite (3CaO.2SiO2.3H2O) of 51.35%, and calcium hydroxide (Ca(OH)2) of 22%. There was no formation of Friedel’s salt in the fresh water concrete because there was no mutual reaction between chloride and calcium hydroxide elements. From the regression analysis, showed that the difference of microstructure compressive strength differences caused by differences in the microstructure of the content of the two types of concrete.
Inundation due to heavy rain often disturbs traffic flow and porous pavement as a wearing course is one solution to overcome standing water. This asphalt mixture uses an open gradation which is dominated by coarse aggregate with an air cavity content ranging from 20% - 25%. In Indonesia, according to the Indonesian Solid Waste Association (2013), this type of plastic waste ranks second with 5.4 million tons per year and is ranked second in the world as a producer of marine plastic waste after China. This research tries to use plastic waste as an added material in the porous asphalt mixture where the gradation of porous asphalt refers to REAM Specifications, 2008. The type of plastic used is Low Density Polyethilene (LDPE). The levels of plastic waste used were 0%, 2%, 4%, 6%, 8% of the total weight of the mixture. Marshall and Cantabro characteristics tests were conducted to evaluate the resulting mixture. The results of this study indicate that the stability value meets the REAM specifications, namely 350 - 800 kg. Marshall test results with the use of LDPE plastic waste as an additive to the test object meet the characteristics of Marshall except for Marshall Quotient (MQ) and voids filled with bitumen (VFB).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.