Objective: To evaluate the capability of ascitic fluid dipstick results for pH, glucose, and protein in order to predict a low serum-ascites albumin gradient (SAAG) at the bedside of the patient in the emergency department (ED). Methods: This prospective cross-sectional study was conducted during one year in the ED of Afzalipour hospital in Kerman, Iran. All patients with diagnostic or therapeutic paracentesis of ascitic fluid were considered as eligible patients. Exclusion criteria included clinical suspicion for spontaneous bacterial peritonitis (SBP), any contraindications to paracentesis, and patients' refusal to participate in the study. Dipstick values were obtained at the bedside, and SAAG was calculated after the determination of serum and ascitic fluid albumin by laboratory. A low SAAG ascitic fluid was defined as the study outcome. We also used our study population as a test group to evaluate an equation proposed in one previous study: K = 0.012 Protein−0.012 Glucose−3.329 pH+23.498 Results: A total of 50 patients were enrolled in the study. Based on multivariate regression analysis, dipstick values for protein and glucose were independently predictive of a low SAAG ascitic fluid (P = 0.23, OR = 1.04; and P = 0.001, OR = 0.81, respectively). The formula proposed in one of the previous studies was tested by our data set, with sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) at 84%, 83%, 84%, and 80%, respectively. Conclusion: Dipstick test of ascitic fluid for pH, glucose, and protein has an acceptable sensitivity and specificity as a point of care test, but it cannot be recommended as a substitute for SAAG determination based on the current findings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.