Magnetocardiography (MCG) of healthy volunteers has been measured by using a fundamental mode orthogonal fluxgate magnetometer array of 32 channels in a magnetic shielded room (MSR). Sensor heads, which are employed, consist of a 45 mm long U-shaped amorphous wire core and a 1000-turn solenoid pick-up coil of 30 mm in length and 3 mm in outer diameter. The excitation current of 100 kHz with large dc bias current is fed directly into wire cores, which are connected in series, whereas the signal detection circuit is provided to each of the sensor heads. A special technique to avoid mutual interaction between sensor heads is implemented, where all the sensor heads are excited synchronously by using a single ac source. A 2-D array having 32 sensors with 4 cm grid spacing was used to measure MCG signals inside an MSR. Measured data from each channel were first filtered (0.16–100 Hz pass band), then averaged for 2 min synchronously with electrocardiogram's peaks taken from both hands. Noise remaining after the average is about 1.8 pTrms for the band-width of 0.16–100 Hz. The QRS complex and the T-wave are clearly detected.
A new magnetic nanoparticle detection system by using a fundamental mode orthogonal fluxgate (FM-OFG) gradiometer and ac magnetizing coil has been developed. The FM-OFG gradiometer has an active canceling coil on each of its sensor heads against the common magnetic field input to avoid the saturation of the amorphous wire core by a strong ac magnetic field. In addition, the ac magnetizing coil has an adjusting capability to make ac magnetic field strength affecting each of the gradiometer heads equal, which allows us to use a high gain amplifier at the latter stage. Two types of the gradiometer are tested: one is parallel configuration in which two sensor heads are placed in parallel side by side, the other is axial configuration in which two sensor heads are placed axially. Detectable distance was investigated using a 5μL (≈100μg in Fe atomic amount) magnetic nanoparticle sample. The maximum detectable distance for the parallel gradiometer is 17 mm, and that for the axial one is 18 mm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.