ObjectiveRecent many studies have shown that whole body “diffusion-weighted imaging with background body signal suppression” (DWIBS) seems a beneficial tool having higher tumor detection sensitivity without ionizing radiation exposure for pediatric tumors. In this study, we evaluated the diagnostic performance of whole body DWIBS and 18F-FDG PET/CT for detecting lymph node and bone metastases in pediatric patients with neuroblastoma.MethodsSubjects in this retrospective study comprised 13 consecutive pediatric patients with neuroblastoma (7 males, 6 females; mean age, 2.9 ± 2.0 years old) who underwent both 18F-FDG PET/CT and whole-body DWIBS. All patients were diagnosed as neuroblastoma on the basis of pathological findings. Eight regions of lymph nodes and 17 segments of skeletons in all patients were evaluated. The images of 123I-MIBG scintigraphy/SPECT-CT, bone scintigraphy/SPECT, and CT were used to confirm the presence of lymph node and bone metastases. Two radiologists trained in nuclear medicine evaluated independently the uptake of lesions in 18F-FDG PET/CT and the signal-intensity of lesions in whole-body DWIBS visually. Interobserver difference was overcome through discussion to reach a consensus. The sensitivities, specificities, and overall accuracies of 18F-FDG PET/CT and whole-body DWIBS were compared using McNemer’s test. Positive predictive values (PPVs) and negative predictive values (NPVs) of both modalities were compared using Fisher’s exact test.ResultsThe total numbers of lymph node regions and bone segments which were confirmed to have metastasis in the total 13 patients were 19 and 75, respectively. The sensitivity, specificity, overall accuracy, PPV, and NPV of 18F-FDG PET/CT for detecting lymph node metastasis from pediatric neuroblastoma were 100, 98.7, 98.9, 95.0, and 100%, respectively, and those for detecting bone metastasis were 90.7, 73.1, 80.3, 70.1, and 91.9%, respectively. In contrast, the sensitivity, specificity, overall accuracy, PPV, and NPV of whole-body DWIBS for detecting bone metastasis from pediatric neuroblastoma were 94.7, 24.0, 53.0, 46.4 and 86.7%, respectively, whereas those for detecting lymph node metastasis were 94.7, 85.3, 87.2, 62.1, and 98.5%, respectively. The low specificity, overall accuracy, and PPV of whole-body DWIBS for detecting bone metastasis were due to a high incidence of false-positive findings (82/108, 75.9%). The specificity, overall accuracy, and PPV of whole-body DWIBS for detecting lymph node metastasis were also significantly lower than those of 18F-FDG PET/CT for detecting lymph node metastasis, although the difference between these 2 modalities was less than that for detecting bone metastasis.ConclusionThe specificity, overall accuracy, and PPV of whole-body DWIBS are significantly lower than those of 18F-FDG PET/CT because of a high incidence of false-positive findings particularly for detecting bone metastasis, whereas whole-body DWIBS shows a similar level of sensitivities for detecting lymph node and bone metastases to those of 18F-FD...
IntroductionIodinated contrast media are commonly used in medical imaging and can cause hypersensitivity reactions, including rare but severe life-threatening reactions. Although several prophylactic approaches have been proposed for severe reactions, their effects remain unclear. Therefore, we aim to review systematically the preventive effects of pharmacologic and non-pharmacologic interventions and predictors of acute, hypersensitivity reactions.Methods and analysisWe will search the PubMed, EMBASE and Cochrane Central Register of Controlled Trials databases from 1 January 1990 through 31 December 2019 and will examine the bibliographies of eligible studies, pertinent review articles and clinical practice guidelines. We will include prospective and retrospective studies of any design that evaluated the effects of pharmacological and non-pharmacological preventive interventions for adverse reactions of non-ionic iodinated contrast media. Two assessors will independently extract the characteristics of the study and intervention and the quantitative results. Two independent reviewers will assess the risk of bias using standard design-specific validity assessment tools. The primary outcome will be reduction in acute contrast media-induced hypersensitivity reactions. The secondary outcomes will include characteristics associated with the development of contrast media-induced acute hypersensitivity reactions, and adverse events associated with specific preventive interventions. Unique premedication regimens (eg, dose, drug and duration) and non-pharmacological strategies will be analysed separately. Average-risk and high-risk patients will be considered separately. A meta-analysis will be performed if appropriate.Ethics and disseminationEthics approval is not applicable, as this will be a secondary analysis of publicly available data. The results of the analysis will be submitted for publication in a peer reviewed journal.PROSPERO registration numberCRD42019134003
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.