Objectives We investigated the hydrodynamic performance and cusp kinematics of the Ozaki neocuspidized aortic valve in comparison with the native aortic and prosthetic valves in an ex vivo study. Methods Native aortic valves of swine hearts were replaced by aortic valve substitutes, and their hydrodynamic performance (effective orifice area and mean pressure gradient) was evaluated in a mock circulation under defined conditions. The following aortic valve substitutes were investigated: native aortic valve, Ozaki valve, Perimount Magna Ease, Trifecta and St. Jude Medical Masters. All prosthetic valves had a labelled size of 21 mm. Results The Ozaki valve and native aortic valve showed a similar and significantly larger orifice area than all investigated prosthetic valves particularly at high flow rates. There was no significant difference between the Ozaki valve and the native aortic valve. The native aortic valve and Ozaki valve showed a similar increase of orifice area with increasing flow through the valve while prosthetic valves showed a markedly weaker increase. Similarly, the native and Ozaki valve showed a similar increase of mPG with forward flow which was weaker than prosthetic valves. Cusp kinematics were similar between the native and Ozaki valve whilst prosthetic valves were clearly distinguishable from them. Conclusions The Ozaki procedure showed excellent hydrodynamic performance compared to prosthetic valves and showed similar cusp motion characteristics to the native aortic valve. Our results suggest that the Ozaki neocuspidized valve behaves physiologically in many aspects which may contribute to beneficial clinical outcomes.
OBJECTIVES Surgical aortic valve replacement (SAVR) in small annuli carries an elevated risk for the patient–prosthesis mismatch. In this study, we systematically investigated the influence of different implantation techniques including annular enlargement (AE) on the functional result after SAVR in small annuli using a standardized ex vivo model. METHODS SAVR using the PERIMOUNT Magna Ease® (PME) 21 mm was performed in small porcine aortic roots using 4 implantation techniques: non-everting pledgeted (NE) suture, single interrupted (SI) suture, continuous suture (CS), figure-of-8 (F8) suture, as well as the PME 23 mm after AE using the Nunez method and the NE suture technique (PME23 AE). The effective orifice area (EOA), mean pressure gradient and leakage volume were evaluated using a mock circulation loop in accordance with ISO regulations. RESULTS Experiments were conducted on 31 porcine aortic roots. PME21 using F8 and PME23 after AE achieved a significantly larger EOA than using NE. PME23 after AE showed a larger EOA than the PME21 using any suture technique, except the F8 [for stroke volume of 74 ml: PME21 NE: 1.68 (1.63–1.72) cm2, PME21 SI: 1.76 (1.68–1.81) cm2 (P = 0.17), PME21 CS: 1.76 (1.65–1.79) cm2 (P = 0.14), PME21 F8: 1.81 (1.70–1.85) cm2 (P = 0.005); PME23 AE: 1.83 (1.73–1.92) cm2 (P < 0.001)]. SI and CS did not result in larger EOA compared with the NE technique. PME21 using SI had a significantly larger leakage volume than using NE and there was no significant difference between other techniques [for stroke volume of 74 ml: PME21 NE: 3.51 (1.85–4.53) ml/stroke, PME21 SI: 6.00 (4.02–7.06) ml/stroke (P < 0.001), PME21 CS: 4.04 (3.60–4.49) ml/stroke (P = 0.10), PME21 F8: 3.16 (1.99–3.62) ml/stroke (P = 0.74), PME23 NE: 2.89 (2.45–4.72) ml/stroke (P = 0.51)]. CONCLUSIONS The F8 technique with the PME21 achieved a similar EOA as the 1 size larger PME23 using NE after AE. These results suggest that the F8 technique may be an effective surgical modification to improve the haemodynamic result in a small annulus without additional AE.
Background Florida sleeve technique was reported by Hess et al. as a new technique of valve sparing aortic root replacement without the requirement of entire aortic root wall resection and coronary artery reconstruction. We present a rare case of an unruptured aneurysm of the right sinus of Valsalva that was successfully treated with resection of the aneurysm and the Florida sleeve technique. Case presentation A 72-year-old man was admitted for the treatment of an unruptured aneurysm of the right sinus of Valsalva. Computed tomography showed an aneurysm of the right sinus of Valsalva measuring > 40 mm and protruding into the right ventricular outflow tract. The aneurysm dilated up to 5 mm per year, and the left sinus of Valsalva and non-coronary sinus of Valsalva also showed dilation, and he underwent resection of only the right sinus of Valsalva aneurysm and valve sparing aortic root replacement with the Florida sleeve technique. Conclusions We performed valve-sparing aortic root replacement with the Florida sleeve technique. It could reduce surgical risks and prevent a dilatation of the residual sinus of Valsalva through coverage with a graft for a long term.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.