Wilson disease (WD) is an autosomal recessive disorder of copper metabolism. The gene responsible for WD was discovered in 1993 and is located on chromosome 13 at 13q14.3. It encodes a copper-specific transporting P-type ATPase. Early diagnosis can improve treatment outcome and decrease the rate of disability or even mortality.We used Sanger sequencing to identify mutation hot spots in 55 northern Vietnamese with a clinical diagnosis of WD. Mutations were screened and detected by direct DNA sequencing. A total of 26 different ATP7B gene mutations were identified, including seven novel mutations (five nonsense and two missense mutations). The most frequent mutations were p.Ser105Ter (24.55%), p.Arg778Leu (5.45%) and p.Thr850Ile (4.55%). Mutation detection rate in exon 2 was 34.55% and ranked first, followed by exon 8 with 16.36%, and exon 18 with 10.91% each, thus, exons 2, 8 and 18 are the mutation hot spots for northern VietnameseWD patients. These findings were different from previous studies in Asia. Our research established a suitable strategy for ATP7B gene testing in northern Vietnamese WD patients.
Objectives The 5α-reductase-type-2 deficiency (5ARD2) is a rare autosomal recessive 46,XY disorder of sex development caused by the mutated 5α-reductase type 2 (SRD5A2) gene. In this disease, defective conversion of testosterone to dihydrotestosterone leads to variable presentations of male ambiguous genitalia during fetal development. We aimed to examine characteristics of patients presenting with 5ARD2 over a 4 year period. Methods Random urine samples of control and patients with suspected 5ARD2 were collected and urine steroidomic metabolites were measured by Gas chromatography-mass spectrometry (GC-MS) in the period from 2017 to 2021 at National Children’s Hospital, Hanoi Vietnam. 5α- to 5β-reduced steroid metabolite ratio, 5a-tetrahydrocortisol to tetrahydrocortisol (5α-THF/THF), was reviewed by receive operator characteristics (ROC) curve analysis. Molecular testing was offered to 25 patients who were diagnosed with 5ARD2 by GC-MS urinary steroid analysis. Results Urine steroidomic profiling was conducted for 104 male controls and 25 patients between the ages of 6 months and 13 years old. Twelve of the twenty-five 5ARD2 patients agreed to undertake genetic analysis, and two mutations of the SRD5A2 gene were detected in each patient, confirming the diagnosis. All patients showed a characteristically low ratio of 5α-THF/THF. There was no overlap of 5α-THF/THF ratio values between control and 5ARD2 groups. The ROC of 5α-THF/THF ratio at 0.19 showed 100% sensitivity and 100% specificity for boys between 6 months and 13 years of age. Conclusions Analysis of the urine steroid metabolome by GC-MS can be used to assist in the diagnosis of 5ARD2. We recommend consideration of random urine steroid analysis as a first-line test in the diagnosis of 5ARD2.
Method validation is an essential laboratory requirement to ensure reliable test results for diagnosis and treatment. This study aims to evaluate the determination of blood glucose level method by the Accu-chek Inform II analyzer at Hanoi Medical University Hospital. Method and materials: Internal control materials were provided by the manufacturer to conduct experiments to evaluate the precision, accuracy and linearity of blood glucose testing on the Accu-chek Inform II analyzer according to the guideline EP15A3 of the Clinical and Laboratory Standards Institute. Results: The within-run precision and within-laboratory precision of two experimental quality control levels are less than the manufacturer’s claim, the observed mean is not within the verification interval, but the Bias is less than the allowable Bias. The accuracy and precision of the blood glucose test performed on the Accu-chek Inform II analyzer used at the Hanoi Medical University Hospital were confirmed in accordance with the manufacturer’s claims.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.