SummaryWe performed a 5-year, retrospective study using records of 1081 patients admitted to the trauma emergency room at a University Hospital to investigate the occurrence of tracheal tube malpositioning after emergency intubation in both the inpatient and outpatient settings, using chest radiographs and CT scans in the trauma emergency room. Prehospital patients and inpatients referred from peripheral hospitals were compared. This study showed that tracheal tube misplacements occur with an incidence of 18.2%, of which almost a third (5.7%) were placed in a main bronchus. We further show that tracheal intubation in emergency patients approximates the misplacement rates in the prehospital or in-hospital settings. We speculate that the skill level of the operator may be critical in determining the success of tracheal intubation. Based on our findings, all efforts should be made to verify the tube position with immediate radiographic confirmation after admission to the emergency room.
Tube thoracostomy positioning mostly depends on the discretion of the physician on scene. The Monaldi and Bülau positions do not differ in misplacement or complication rates.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.