McCune-Albright syndrome (MAS) is a rare disorder that develops from an activating mutation in the Gs gene. It is characterized by an association with Polyostotic fibrous dysplasia, and precocious puberty, Caf-au-lait pigmentation, and other endocrinopathies that result from the hyperactivity of a variety of endocrine glands. Recently we encountered a patient with MAS with fibrous dysplasia, skin pigmentation, acromegaly, hyperprolactinemia and a thyroid nodule. A 23-year-old male presented for an evaluation of a change in his facial structures. Fibrous dysplasia was diagnosed by a bone biopsy and radiographic studies. The GH level increased paradoxically after an oral glucose load. The plasma prolactin, IGF-1 and alkaline phosphatase were high. Thyroid ultrasonography revealed multiple nodules. The brain MRI demonstrated a mass in the left pituitary gland. Genetic analysis identified a change from Arg (CGT) at codon 201 to Cys (TGT).
Nanoscopic synchrotron X-ray imaging was performed on scalp hair samples of patients with breast cancer and healthy individuals to investigate any structural differences as diagnostic tool. Hair strands were divided into 2-3 segments along the strands from root to tip, followed by imaging either in projection or in CT scanning with a monochromatic 6.78-keV X-ray using zone-plate optics with a resolving power of 60 nm. All the examined cancer hairs exhibited medulla loss with cancer stage-dependent pattern; complete loss, discontinuous or trace along the strands. In contrast, medullas were well retained without complete loss in the healthy hair. In the CT-scanned axial images, the cortical spindle compartments had no contrast in the healthy hair, but appeared hypointense in contrast to the surrounding hyperintense cortical membrane complex in the cancer hair. In conclusion, observation of medulla loss and cortical membrane enhancements in the hair strands of breast cancer patients demonstrated structural variations in the cancer hair, providing a new platform for further synchrotron X-ray imaging study of screening breast cancer patients.
High-resolution tomographic images using synchrotron X-rays are expected to provide detailed reflection of microstructures, thereby allowing for the examination of histologic structures without destruction of the specimen. This study aims to evaluate the synchrotron tomographic images of mixed ground-glass opacity excised on 5-mm sections in comparison to pathologic examination. The Institutional Review Board of our institute approved this retrospective study, and written informed consent was obtained from each patient whose lung tissue would be used. Obtained lung cancer specimens were brought to the multiple Wiggler 6C beam line at the Pohang Light Source (PLS-II) in Korea, and phase contrast X-ray images were obtained in November 2016. The X-ray emanated from a bending magnet of the electron storage ring with electron energy of 3 GeV, and a typical beam current was 320 mA. Reconstructed tomographic images were compared with images from histologic slides obtained from the same samples. Pulmonary microstructures including terminal bronchioles, alveolar sacs, and vasculature were identified with phase contrast X-ray images. Images from normal lung tissue and mixed ground-glass opacity were clearly distinguishable. Hyperplasia of the interalveolar septum and dysplasia of microstructure were clearly identified. The imaging findings correlated well with hematoxylin-eosin stained specimens. Tomographic images using synchrotron radiation have the potential for clinical applications. With refinement, this technique may become a diagnostic tool for detection of lung cancer.
Phase-contrast synchrotron X-ray microtomography (pcSyncX) based on the highly coherent X-ray beam has previously been used to visualize the microstructures of biologic specimens, but it has never been used to evaluate embolic debris adherent on a cerebral protection device (CPD). The purpose of this study was to demonstrate the feasibility of pcSyncX for evaluating embolic debris during carotid artery stenting (CAS). Five patients (four males, age range 67-77 years) with severe carotid artery stenosis underwent CAS. The retrieved CPD was exposed to synchrotron radiation and 1000 pcSyncX projection images were obtained by rotating the CPD through 180°. An X-ray shadow of a CPD was converted into a visual image by the scintillator. After microtomographic reconstruction, the three-dimensionally reconstructed images were further segmented into the embolic debris and CPD. The total volume of emboli was calculated by summing the volume at each scanning level. The number of membrane pores covered by emboli as seen from the outer surface was counted and the percentage of covered area was calculated. Embolic debris was clearly demonstrated not only on the inner surface and within pores but also on the outer surface of the CPD. The mean total volume of embolic debris was 0.538 × 10(-6) mm(3) (range 0.225-0.965 × 10(-6) mm(3)). Most (61.5%) of the debris was located at the apical one-third of the CPD and 20.8% of the pore area was covered by debris.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.