Micro-combustor can provide the required thermal energy of micro-thermal photovoltaic (MTPV) systems. The performance of MTPV is greatly affected by the effectiveness of a micro-combustor. In this study, a numerical simulation was conducted to explore the benefits of annular rectangular rib for enhancing the thermal performance of a nonpremixed micro-combustor. Based on the investigations under various rib heights, rib positions, and inlet mass flow rates, it is found that the addition of annular rectangular ribs in the micro-combustor creates a turbulent zone in the combustion chamber, thereby enhancing the heat transfer efficiency between the inner wall of the combustion chamber and the burned gas. The micro-combustor with annular rectangular rib shows a higher and more uniform wall temperature. When the H2 mass flow is 7.438 × 10−8 kg/s and the air mass flow is 2.576 × 10−6 kg/s, the optimum dimensionless rib position is at l = 6/9 and r = 0.4. At this condition, the micro-combustor has the most effective and uniform heat transfer performance and shows significant decreases in entropy generation and exergy destruction. However, the optimum l and r significantly depend on the inlet mass flow of H2/air mixture.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.