This study suggests that a final stature prediction method using multiple regression analysis that includes biological parameters can predict stature growth with sufficient validity and accuracy. Incorporation of TO-related parameters allowed us to develop earlier growth evaluation and prediction methods compared with other previous methods.
Purpose
To measure surface roughness before and after wear‐tests of two different prefabricated composite veneers and compare them to ceramic veneers and human dental enamel.
Materials and Methods
Roughness (Ra‐values) of two prefabricated composite veneers (Visalys Veneer Chairside (VIS) and Componeer (COM)) were compared to lithium disilicate Veneers (e.max CAD) and dental enamel (DENT) in vitro. In total n = 45 specimens per material and enamel samples were used for wear‐tests. Wear‐out tests were conducted by abrasion tests with a toothbrush simulator (22,000 strokes/ 100 g load; approximately equal to two years of cleansing) and erosion tests were carried out using citric acid (pH 1.57). Ra‐ and Sa‐values were detected by white light interferometer before and after wear‐tests. Data were analyzed with ANOVA followed by Games‐Howell post hoc test and t‐test (α = 0.05).
Results
At baseline the lowest Ra‐ and Sa‐values were found in VIS (Ra: 0.01 µm; Sa: 0.04 µm) while DENT revealed significantly higher surface roughness (Ra: 0.11 µm, p < 0.05; Sa: 0.30, p = 0.186). COM had significantly higher Ra‐values (Ra: 0.10 µm; Sa: 0.22 µm) after abrasion, while e.max CAD was most resistant to the treatments (Ra: 0.01 µm, p < 0.05; Sa: 0.05 µm, p < 0.05). Compared to DENT all veneers were significantly less affected by citric acid (p < 0.001).
Conclusions
Prefabricated composite veneers have demonstrated less wear after abrasion and erosion tests compared to DENT, nevertheless, they revealed more wear compared to e.max CAD.
The use of temporary cement did not have a significant influence on retention of permanently cemented crowns when zinc phosphate cement was used for permanent cementation. Airborne-particle abrasion after provisional cementation improved retention of crowns cemented with zinc phosphate cement; however, the use of temporary cement significantly decreased retention of permanently cemented crowns when RMGI cement was used regardless of the temporary cement cleaning method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.