In this paper, centrifuge-based microfluidic platforms are reviewed and compared with other popular microfluidic propulsion methods. The underlying physical principles of centrifugal pumping in microfluidic systems are presented and the various centrifuge fluidic functions, such as valving, decanting, calibration, mixing, metering, heating, sample splitting, and separation, are introduced. Those fluidic functions have been combined with analytical measurement techniques, such as optical imaging, absorbance, and fluorescence spectroscopy and mass spectrometry, to make the centrifugal platform a powerful solution for medical and clinical diagnostics and high throughput screening (HTS) in drug discovery. Applications of a compact disc (CD)-based centrifuge platform analyzed in this review include two-point calibration of an optode-based ion sensor, an automated immunoassay platform, multiple parallel screening assays, and cellular-based assays. The use of modified commercial CD drives for high-resolution optical imaging is discussed as well. From a broader perspective, we compare technical barriers involved in applying microfluidics for sensing and diagnostic use and applying such techniques to HTS. The latter poses less challenges and explains why HTS products based on a CD fluidic platform are already commercially available, whereas we might have to wait longer to see commercial CD-based diagnostics.
Today, the focus in microfluidic platforms for diagnostics is on the integration of several analysis steps toward sample-to-answer systems. One of the main challenges to integration is the requirement for serial valving to allow the sequential release of fluids in a temporally and spatially controlled manner. The advantages offered by centrifugal microfluidic platforms make them excellent candidates for integration of biological analysis steps, yet they are limited by the lack of robust serial valving technologies. This is especially true for the majority of centrifugal microfluidic devices that rely on hydrophilic surfaces, where few passive serial valving techniques function reliably. Building on the useful functionality of centrifugal microfluidic siphoning previously shown, a novel serial siphon valve is introduced that relies on multiple, inline siphons to provide for a better controlled, sequential release of fluids. The introduction of this novel concept is followed by an analytical analysis of the device.Proof-of-concept is also demonstrated, and examples are provided to illustrate the range of functionality of the serial siphon valve. The serial siphon is shown to be robust and reproducible, with variability caused by the dependence on contact angle, rotation velocity, and fluidic properties (viz., surface tension) significantly reduced compared to current microfluidic, centrifugal serial valving technologies.
The applications of microfluidic technologies in medical diagnostics continue to increase, particularly in the field of nucleic acid diagnostics. While much attention has been focused on the development of nucleic acid amplification and detection platforms, sample preparation is often taken for granted or ignored all together. Specifically, little or no consideration is paid to the development of microfluidic systems that efficiently extract nucleic acids from biological samples. Here, a centrifugal microfluidic platform for mechanical sample lysis and homogenization is presented. The system performs sample lysis through a magnetically actuated bead-beating system followed by a centrifugal clarification step. The supernatant is then transferred for extraction using a unique siphon. Several other new microfluidic functions are implemented on this centrifugal platform as well, including sample distribution, a unique hydraulic capillary valve, and self-venting. Additionally, the improved system has features with a small footprint designed specifically for integration with further downstream processing steps. Biological validation of the platform is performed using Bacillus subtilis spores and clinical samples (nasopharyngeal aspirates) for respiratory virus detection. The platform was found to be as efficient as in-tube bead-beating lysis and homogenization for nucleic acid extraction, and capable of processing 4 samples in batch to near PCR-ready products in under 6 min.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.