Dislocation of an intraocular lens (IOL) with the capsular bag is a late complication of cataract surgery, reported with increasing frequency in recent years. Pseudoexfoliation, uveitis, myopia, and other diseases associated with progressive zonular weakening and capsular contraction are the predisposing conditions. Capsular tension rings probably help but do not prevent this complication. Management includes IOL exchange, replacement with an anterior or a sutured posterior chamber IOL, or suturing the IOL through the bag to the iris or the sclera.
The development of the continuous circular capsulorhexis (CCC) technique has contributed significantly to the safety and effectiveness of cataract extraction and intraocular lens implantation. This technique facilitates every size of smooth, circular, capsular opening, and it produces a strong capsular rim that resists tearing even when stretched during lens material removal or lens implantation. Maintaining the general integrity of the eye and facilitating such procedures as hydrodissection, endolenticular phacoemulsification, capsule polishing, and safe lens implantation in both adults and children are some of the advantages of CCC. This procedure can be performed in several ways, and it has been proven to be consistently reproducible by experienced surgeons.
We compared the predictive accuracy of the SRK/T formula to the SRK II, Binkhorst II, Hoffer, and Holladay formulas in seven series of cases totaling 1,050 eyes. In the combined group, the SRK/T and Holladay formulas performed only slightly better than the other formulas. In short eyes (less than 22 mm), all formulas performed well, with the SRK/T, SRK II, and Holladay formulas performing marginally better. In moderately long eyes (greater than 24.5 mm, less than or equal to 27 mm), the Hoffer and Binkhorst II formulas had a greater proportion of cases with greater than 2 diopters (D) of error and the SRK/T and Holladay were again marginally better. In the very long eyes (greater than 27 mm and less than or equal to 28.4 mm), there were only 11 cases and all formulas performed well since none had greater than 2 D of prediction error. In an extremely long eye data set (greater than 28.4 mm), the SRK II formula clearly gave the poorest result. Eyes of this length occurred in only 0.1% of cases in our unselected series. Results support the contention that the present second and third generation IOL power formulas give fairly equivalent accuracy. Other factors, such as availability, ease of use, and ability to tailor or individualize, become major considerations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.