In this paper, a seven-rod bare bundle was simulated using ANSYS Fluent 6.3.26 to accurately predict the fluid flow and heat transfer behaviour under supercritical flow conditions. Seven turbulence models were compared to identify the appropriate model to predict the experiments performed at the Institute of Physics and Power Engineering on a vertically oriented seven-rod bare bundle cooled with supercritical Freon-12. It was found that predictions of wall temperatures and heat transfer coefficients are sensitive to the choice of turbulence model as well as to the near-wall treatment. Overall, the CFD simulations were able to predict the measured sheath temperature profiles along the length of the bundle within reasonable accuracy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.