Microfluidic techniques have been recently developed for cell-based assays. In microfluidic systems, the objective is for these microenvironments to mimic in vivo surroundings. With advantageous characteristics such as optical transparency and the capability for automating protocols, different types of cells can be cultured, screened, and monitored in real time to systematically investigate their morphology and functions under well-controlled microenvironments in response to various stimuli. Recently, the study of stem cells using microfluidic platforms has attracted considerable interest. Even though stem cells have been studied extensively using bench-top systems, an understanding of their behavior in in vivo-like microenvironments which stimulate cell proliferation and differentiation is still lacking. In this paper, recent cell studies using microfluidic systems are first introduced. The various miniature systems for cell culture, sorting and isolation, and stimulation are then systematically reviewed. The main focus of this review is on papers published in recent years studying stem cells by using microfluidic technology. This review aims to provide experts in microfluidics an overview of various microfluidic systems for stem cell research.
Via immunomagnetic reduction assay, biomolecules can be quantitatively detected with aid of biofunctionalized magnetic nanoparticles, which are used as labeling markers for specific biomolecules. To achieve ultra-high sensitivity in detecting biomolecules, superconducting quantum interference device (SQUID) is a promising candidate to act as a sensor to the magnetic signal related to the concentration of detected biomolecules. In the past, we developed a single channel SQUID-based magnetosusceptometry. In order to increase the detection through-put, multichannel SQUID-based magnetosusceptometry is developed. In this work, the design and working principle of four-channel SQUID-based magnetosusceptometry are introduced. Using utilizing scanning technology, four samples can be simultaneously logged into the SQUID-based magnetosusceptometry. Notably, only single SQUID magnetometer is used in the magnetosusceptometry. The precision and sensitivity in detecting biomolecules using the four-channel SQUID-based magnetosusceptometry are investigated.
Abstract:The conventional hanging drop technique is the most widely used method for embryoid body (EB) formation. However, this method is labor intensive and limited by the difficulty in exchanging the medium. Here, we report a microfluidic chip-based approach for high-throughput formation of EBs. The device consists of microfluidic channels with 6ˆ12 opening wells in PDMS supported by a glass substrate. The PDMS channels were fabricated by replicating polydimethyl-siloxane (PDMS) from SU-8 mold. The droplet formation in the chip was tested with different hydrostatic pressures to obtain optimal operation pressures for the wells with 1000 µm diameter openings. The droplets formed at the opening wells were used to culture mouse embryonic stem cells which could subsequently developed into EBs in the hanging droplets. This device also allows for medium exchange of the hanging droplets making it possible to perform immunochemistry staining and characterize EBs on chip.
This study reports an integrated microfluidic system capable of isolation, counting, and sorting of hematopoietic stem cells (HSCs) from cord blood in an automatic format by utilizing a magnetic-bead-based immunoassay. Three functional modules, including cell isolation, cell counting, and cell sorting modules are integrated on a single chip by using microfluidic technology. The cell isolation module is comprised of a four-membrane-type micromixer for binding of target stem cells and magnetic beads, two pneumatic micropumps for sample transport, and an S-shaped channel for isolation of HSCs using a permanent magnet underneath. The counting and sorting of HSCs are performed by utilizing the cell counting and sorting modules. Experimental results show that a separation efficiency as high as 88% for HSCs from cord blood is achieved within 40 min for a sample volume of 100 mul. Therefore, the development of this integrated microfluidic system may be promising for various applications such as stem cell research and cell therapy.
In vitro testing of drug compounds on cell models during the drug development process represents an indispensable step in the initial screening process. Although drug testing on three-dimensional (3D) cultured cells may provide a more accurate prediction of drug efficacy, it is relatively costly and time-consuming to perform compared with conventional 2D cultures due to the thick z-axis of the 3D models. In this study, we have presented a microfluidic platform with integrated pneumatic valves for producing a thin-gel 3D cell culture-based combinatorial drug screening array (3D-μCDS array). The multilayer architecture and microfluidic layout has a smaller device footprint than a single-layer microfluidic channel arrangement, making it well suited to scaling up for high-throughput combinatorial drug screening on 3D cell model. We performed 8 × 8 combination drug screening experiments with the device using two anti-cancer drugs (doxorubicin and paclitaxel) on MDA-MB-231 and MCF-7 breast cancer cell lines for demonstration. Our results indicate that our 3D-μCDS array device allows the successful screening of multiple drug combinations while reducing the operation time and the number of sample/reagents required, making it an ideal tool for general combinatorial drug screening, as well as for applications using valuable tissues and clinical samples.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.