<p>The online impedance serves as one of the most crucial specification to evaluate the health status and efficiency of an electrical device or system. The inductive coupling technique is a preferred approach to measure the online impedance due to the ease of implementation of the circuit which has zero physical contact to the live electrical system. The existing inductive coupling method deployed to measure the online impedance of an electrical device under test (DUT) adopts two probes in total: an injecting inductive probe (IIP) and a receiving inductive probe (RIP). An open/short/load (OSL) calibration procedure is implemented to eradicate the ramifications of the probe-to-probe coupling, however, based on the assumption that the calibration criterions (shorted, open and 50Ω) are approximated to their theoretical values in a specified frequency range. Hence, any measurement with frequency outside the specified range (i.e. larger than 1 MHz) will not be accurate due to the frequency-dependent residual inductances and capacitances of the calibration model. To overcome the aforesaid limitation, this paper introduces an improved calibration procedure which is applicable for a wider frequency range which takes the frequency-dependent characteristics into consideration. With the two-probe measurement setup (TPMS), the adopted improved calibration procedure is introduced to eradicate the ramifications of the probe-to-probe coupling with the intention to refine the accuracy of the extracted online impedance.<a></a></p><p></p>
<p>The online impedance serves as one of the most crucial specification to evaluate the health status and efficiency of an electrical device or system. The inductive coupling technique is a preferred approach to measure the online impedance due to the ease of implementation of the circuit which has zero physical contact to the live electrical system. The existing inductive coupling method deployed to measure the online impedance of an electrical device under test (DUT) adopts two probes in total: an injecting inductive probe (IIP) and a receiving inductive probe (RIP). An open/short/load (OSL) calibration procedure is implemented to eradicate the ramifications of the probe-to-probe coupling, however, based on the assumption that the calibration criterions (shorted, open and 50Ω) are approximated to their theoretical values in a specified frequency range. Hence, any measurement with frequency outside the specified range (i.e. larger than 1 MHz) will not be accurate due to the frequency-dependent residual inductances and capacitances of the calibration model. To overcome the aforesaid limitation, this paper introduces an improved calibration procedure which is applicable for a wider frequency range which takes the frequency-dependent characteristics into consideration. With the two-probe measurement setup (TPMS), the adopted improved calibration procedure is introduced to eradicate the ramifications of the probe-to-probe coupling with the intention to refine the accuracy of the extracted online impedance.<a></a></p><p></p>
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.