Purposes: This study discussed the accommodative response and pupil size of myopic adults using a double-mirror system (DMS). The viewing distance could be extended to 2.285 m by using a DMS, which resulted in a reduction and increase in the accommodative response and pupil size, respectively. By using a DMS, the reduction of the accommodative response could improve eye fatigue with near work. Method: Sixty subjects aged between 18 and 22 years old were recruited in this study, and the average age was 20.67 ± 1.09. There were two main steps in the experimental process. In the first step, we examined the subjects’ refraction state and visual function, and then fitted disposable contact lenses with a corresponding refractive error. In the second step, the subjects gazed at an object from a viewing distance of 0.4 m and at a virtual image through a DMS, respectively, and the accommodative response and pupil size were measured using an open field autorefractor. Results: When the subjects gazed at the object from a distance of 0.4 m, or gazed at the virtual image through a DMS, the mean value of the accommodative response was 1.74 ± 0.43 or 0.16 ± 0.47 D, and the pupil size was 3.98 ± 0.06 mm or 4.18 ± 0.58 mm, respectively. With an increase in the viewing distance from 0.4 m to 2.285 m, the accommodative response and pupil size were significantly reduced about 1.58 D and enlarged about 0.2 mm, respectively. For three asterisk targets of different sizes (1 cm × 1 cm, 2 cm × 2 cm, and 3 cm × 3 cm), the mean accommodative response and pupil size through the DMS was 0.19 ± 0.16, 0.27 ± 0.24, 0.26 ± 0.19 D; and 4.20 ± 1.02, 3.94 ± 0.73, 4.21 ± 0.57 mm, respectively. The changes of the accommodative response and pupil size were not significant with the size of the targets (p > 0.05). In the low or high myopia group, the accommodative response of 0.4 m and 2.285 m was 1.68 ± 0.42 D and 0.21 ± 0.48 D; and 1.88 ± 0.25 D and 0.05 ± 0.40 D, respectively. The accommodative response was significantly reduced by 1.47 D and 1.83 D for these two groups. The accommodative microfluctuations (AMFs) were stable when a DMS was used; on the contrary, the AMFs were unstable at a viewing distance of 0.4 m. Conclusions: In this study, the imaging through a DMS extended the viewing distance and enlarged the image, and resulted in a reduction in the accommodative response and an increase in the pupil size. For the low myopia group and the high myopia group, the accommodative response and pupil size were statistically significantly different before and after the use of the DMS. The reduction of the accommodative response could be applied for the improvement of asthenopia.
Purpose: This paper discusses the accommodative relaxation of myopic adults using a simple double-mirror design. This optical design can extend the viewing distance to 2.285 m and can magnify the image up to 3.386 times, and it results in the accommodative relaxation of a single human eye. By using this optical design, accommodative relaxation may improve eye fatigue and, furthermore, it may delay the progression of myopia. Method: This study recruited 32 subjects with an average age of 20.8 ± 0.95 years old. After an examination of their refractive status, disposable contact lenses with a corresponding refractive error were fitted, and the dynamic accommodative response and change in pupil size were measured by using an open-field autorefractor. The subjects gazed at two different viewing distances. First, they gazed at a real object, which was placed 0.4 m in front of them. Second, the subjects gazed at a virtual image through a double-mirror system at a distance of 2.285 m. The dynamic accommodative responses and pupil size data were collected under these two viewing distance conditions. Results: When the subjects gazed at a real object that was 0.4 m away, or a virtual image that was 2.285 m away, the mean value of the accommodative response was 1.69 ± 0.31 D or 0.11 ± 0.05 D, and the pupil size was 3.79 ± 0.49 mm or 4.09 ± 0.72 mm, respectively. The accommodative response decreased, and the pupil size increased when using the double-mirror system, and therefore, accommodative relaxation can be achieved by using this new optical design. Conclusions: In the present study, we first successfully proposed a simple optical design to relax the accommodation, and the fluctuations of the accommodation response were stable, with an extended viewing distance of 2.285 m. This design may be applied for the improvement of visual function in applications such as the reduction of asthenopia and the control of myopia.
This paper discusses the accommodative relaxation of myopic adults by using a simple double-mirror design. This optical design can extend the viewing distance to 2.285 m and magnify the image up to 3.79 times, and it results in the accommodative relaxation of a single human eye. We recruited 32 subjects with an average age of 20.8 ± 0.95 years old. After an examination of their refractive status, the disposable contact lenses with a corresponding refractive error were corrected, and the dynamic accommodative response and the change in pupil size were measured by using an open-field auto-refractor. The dynamic accommodative responses and pupil size data were collected under two viewing distance conditions. When the subjects gazed at a real object that was 0.4 m away, or a virtual image that was 2.285 m away, the mean value of the accommodative response was 1.69 ± 0.31D or 0.11 ± 0.05D, and the pupil size was 3.79 ± 0.49 mm or 4.09 ± 0.72 mm, respectively. The accommodative response decreased and the pupil size increased by using the double-mirror system, and therefore, accommodative relaxation can be achieved by using this new optical design. In this study, we first successfully proposed a simple optical design to relax the accommodation, and the fluctuations of the accommodation response were stable, with the extended viewing distance of 2.285 m. This design may be applied for the improvement of visual function, such as the reduction of asthenopia and the control of myopia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.