BackgroundThe purpose of this study is to report the prevalence, etiology, treatment and outcomes of neovascular glaucoma (NVG) in a tertiary care ophthalmic center in China.MethodsMedical records of patients diagnosed as NVG at the Wenzhou Medical University between 2003 and 2014 were reviewed. Success was defined as IOP between 6 and 21 mmHg without topical or systemic glaucoma medications with retention of presenting visual acuity (VA).ResultsNVG was diagnosed in 483 of 8306 (5.8 %) of all glaucoma patients. Etiology is reported for all 310 eyes of 284 patients managed in the department. Interventions depended on insurance as well as personal finances; outcomes are reported for the 149 eyes of 138 patients with complete data that met follow up requirements. Diabetic retinopathy (DR,39.7 %) was the major cause of NVG. Kaplan Meier survival analysis showed a success rate of 84.8 % at 1 year, 47.5 % at 3 years and 21.9 % at 5 years. Major interventions included glaucoma drainage device (GDD) in 103 eyes and trans-scleral cyclophotocoagulation (TSCPC) in 22 eyes. Complications were more common in the GDD group.ConclusionsNVG comprised 5.8 % of glaucoma patients seen in a tertiary Chinese hospital. DR was identified as the commonest cause and probably reflects the increasing prevalence of diabetes in China. Surgical interventions were partly determined by insurance status and personal finances. GDD was the commonest surgical intervention used and also had the most complications.
We present the design, fabrication, and characterization of a dual-surface sphero-cylindrical progressive addition lens (DSOC-PAL), which combines the progressive cylindrical addition power of both lens surfaces to give the required spherical addition power. Both the freeform lens surfaces are numerically solved with the variational-difference numerical method based on the minimization of a merit function that employs weight functions and boundary conditions to balance between the desired spherical power distribution and the necessary cylindrical power distribution. The simulation results show that the proposed DSOC-PAL design is highly tolerant to the surface alignment errors and agree well with the experimental results obtained by the lens surfacing and polishing process.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.