The study was aimed at exploring the diagnostic value of artificial intelligence reconstruction algorithm combined with CT image parameters on hepatic ascites, expected to provide a reference for the etiological evaluation of clinical abdominal effusion. Specifically, the adaptive iterative hard threshold (AIHT) algorithm for CT image reconstruction was proposed. Then, 100 patients with peritoneal effusion were selected as the research subjects. After 8 cases were excluded, the remaining was divided into 50 cases of the S1 group (hepatic ascites) and 42 cases of the D0 group (cancerous peritoneal effusion). Gemstone energy spectrum CT scanning was performed on all patients, and CT image parameters of the two groups were compared. It was found that CT value of mixed energy, CT value of 60-100 KeV single energy, concentration value of water (calcium), concentration value of water (iodine), and slope of energy spectrum curve in the S1 group were significantly lower than those in the D0 group ( P < 0.05 ). The effective atomic number in the S1 group was significantly higher than that in the D0 group ( P < 0.05 ). Of the 50 patients in the S1 group, 3 (6%) had an ascending and 47 (94%) had a descending spectral curve. Of the 42 patients in the D0 group, 37 (88.1%) had an ascending and 5 (11.9%) had a descending spectral curve. The sensitivity and specificity of water (iodine) were 0.927 and 0.836, respectively. The sensitivity and specificity of water (calcium) were 0.863 and 0.887, respectively. For different scan ranges ([0,90]; [0,120]), root mean square error (RMSE) of AIHT reconstructed image was significantly smaller than that of traditional algorithm, while peak signal-to-noise ratio (PSNR) was opposite. The differences were statistically significant ( P < 0.05 ). In conclusion, AIHT-based CT images can better display the distribution of hepatic ascites, and the parameters of CT value, effective atomic number, water (iodine), water (calcium), and spectral curve can all provide help for the identification of hepatic ascites. Especially, water (iodine) and water (calcium) demonstrated high diagnostic performance of hepatic ascites.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.