None of the currently used anti-HIV-1 agents can effectively eliminate latent HIV-1 reservoirs, which is a major hurdle to a complete cure for AIDS. We report here that a novel oral BET inhibitor OTX015, a thienotriazolodiazepine compound that has entered phase Ib clinical development for advanced hematologic malignancies, can effectively reactivate HIV-1 in different latency models with an EC 50 value 1.95-4.34 times lower than JQ1, a known BET inhibitor that can reactivate HIV-1 latency. We also found that OTX015 was more potent when used in combination with prostratin. More importantly, OTX015 treatment induced HIV-1 full-length transcripts and viral outgrowth in resting CD4 + T cells from infected individuals receiving suppressive antiretroviral therapy (ART), while exerting minimal toxicity and effects on T cell activation. Finally, biochemical analysis showed that OTX015-mediated activation of HIV-1 involved an increase in CDK9 occupancy and RNAP II C-terminal domain (CTD) phosphorylation. Our results suggest that the BET inhibitor OTX015 may be a candidate for anti-HIV-1-latency therapies.
In this study, chip-based enantioselective open-tubular CEC (OT-CEC) was developed employing BSA-gold nanoparticle (GNP) conjugates as a chiral stationary phase. An immobilization procedure was realized by prederivatization of the glass microchannel with (3-mercaptopropyl)-trimethoxysilane to provide thiol groups, which linked the BSA-GNP conjugates on the inner surface of the microchannels. Incorporation of GNPs into immobilization of BSA selectors greatly increased the BSA phase ratio and favored the BSA stationary phase generated sufficient EOF. Good resolutions of FITC-labeled ephedrine and norephedrine isomers were achieved with 36 mm effective separation channel length within 250 s. The constructed OT-CEC microdevice exhibited good repeatabilities for run-to-run enantioseparations and kept an enantioselective lifetime of more than 1 month. The effects of pH values and concentrations of a running buffer on the selectivity and resolution of enantioseparations were investigated.
We report a novel chemiluminescence diagnosis system for high-throughput human IgA detection by inkjet nanoinjection on a multicapillary glass plate. As proof-of-concept, microhole-based polydimethylsiloxane (PDMS) sheets were aligned on a multicapillary glass plate to form a microwell array as microreactors for enzyme-linked immunosorbent assay (ELISA). The multicapillary glass plate was utilized as a switch that controlled the holding/passing of the solution. Further, anti-IgA-labeled polystyrene (PS) microbeads was assembled into the microwell array, and an inkjet nanoinjection was specially used to distribute the sample and reagent solution for chemiluminescence ELISA, enabling high-throughput detection of human IgA. As a result, the performance of human IgA tests revealed a wider range for the calibration curve and a lower limit of detection (LOD) of 0.1 ng mL(-1) than the ELISA by a standard 96-well plate. The analysis time and reagent consumption were significantly decreased. The IgA concentrations in saliva samples were determined after 10000-fold dilution by the developed ELISA system showing comparable results by conventional immune assay with 96-wells. Thus, we believe that the inkjet nanoinjection for high-throughput chemiluminescence immunoassay on a multicapillary glass plate will be promising in disease diagnosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.