In recent years, fire accidents in petrochemical plant areas and dangerous goods storage ports in China have shown a trend of frequent occurrence. Toxic and harmful gases are diffused in the scenes of these accidents, which causes great difficulties for fire fighting and rescue operations of fire fighting forces, and consequently, casualties of firefighters often occur. In order to ensure the safety of firefighters in such places, this paper designs a monitoring system of toxic and harmful gases specially used in fire fighting and rescue sites of fire forces, and establishes the transmission network, monitoring terminal and data processing software of the monitoring system of toxic and harmful gases, establishing the danger model of the monitoring area of toxic and harmful gas-monitoring terminal, and the danger model of fire fighters’ working area, fusing the field toxic and harmful gas data, terminal positioning data, and field environmental data, designing the data structure of the input data set and the network structure of the RNN cyclic neural network model, and realizing the dynamic early warning of toxic and harmful gases on site.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.