Radiolabelled leukocytes are useful for the imaging of inflammation and infection, and 18F-fluorodeoxyglucose (18F-FDG) is known to concentrate in metabolically active cells. We evaluated the feasibility of leukocyte labelling with 18F-FDG using ACD and heparin anticoagulants at 20 degrees C and 37 degrees C, with and without gentle mixing during incubation. With leukocytes (WBC) harvested from 20 ml blood, studies were performed using 18F-FDG in concentrations of 3.7-74 MBq (0.1-2.0 mCi). 18F-FDG WBC stability in platelet-poor plasma was assessed at 1-4 h. Satisfactory labelling efficiency was achieved with incubation in heparin-saline at 37 degrees C for 30 min (62.7+/-1.6%), and was further enhanced by mixing during incubation (78.1+/-3.9%). Cell labelling was predominantly of granulocytes (78.5+/-1.4%). 18F-FDG WBC was relatively stable in platelet-poor plasma for up to 4 h, and no cell staining was observed in viability studies using trypan blue. These results indicate the feasibility of leukocyte labelling with 18F-FDG, providing an approach that may be useful in PET imaging of inflammation and infection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.