Purpose To assess alterations in quantitative dynamic pupil responses to light in relation to neurologic disability and retinal axonal loss in patients with multiple sclerosis (MS). Methods Twenty-five patients with relapsing-remitting MS and 25 healthy subjects were included in this cross-sectional study. Pupillary responses were measured with an infrared dynamic pupillometry unit, and peripapillary retinal nerve fiber layer (RNFL) thickness was measured with spectral-domain optical coherence tomography. Neurologic disability was assessed by the Expanded Disability Status Scale (EDSS). Patients with a history of optic neuritis (ON) within 6 months were excluded. Only the right eyes were assessed, except in 11 patients with a history of unilateral ON in whom both eyes were further analyzed to evaluate the effect of previous ON. Results The initial pupil diameter ( P = 0.003) and pupil contraction amplitude ( P = 0.027) were lower in patients with MS compared with healthy controls. Initial pupil diameter correlated with EDSS score (ρ = −0.458; P = 0.021), and RNFL correlated with contraction latency (ρ = −0.524; P = 0.007). There were no significant differences in any of the pupil parameters between eyes with and without a history of ON, and between the ON and fellow eyes of the 11 patients with previous unilateral ON. Conclusions Dynamic pupillometry reveals significant alterations in pupillary light reflex responses associated with neurologic disability and retinal axonal loss, independent of previous ON. Translational Relevance Dynamic pupillometry is a simple, noninvasive tool that may be useful in detecting autonomic dysfunction in patients with MS.
Purpose: To evaluate the clinical findings and ocular surface changes in patients with ankylosing spondylitis (AS). Methods: This prospective study involved 45 patients with AS (group 1) and 28 healthy subjects (group 2). Patients in group 1 were in the inactive period. The study subjects underwent a complete ophthalmic examination. The right eyes of the subjects in each group were tested for the study including slit-lamp examination, Schirmer I test, tear break-up time (TBUT), conjunctival impression cytology (CIC), and ocular surface disease index (OSDI). Results between the two groups were compared. Results: The mean Schirmer I test result was found as 12.2±8 mm in group 1 and 20.3±9.9 mm in group 2 (P<0.001), whereas the mean TBUT value was found as 3.8±1.9 sec in group 1 and 10.1±4.8 sec in group 2 (P<0.001). The OSDI scores were significantly higher in group 1 (36.5±19.4) than in group 2 (9.1±12.9, P<0.001). The CIC scores were significantly higher in group 1 (2.12±0.7) than in group 2 (0.57±0.6, P<0.001). Notably, none of the patients in group 1 showed grade 0 differentiation, and none of the patients in group 2 showed grade 2 or 3 differentiation. The CIC scores were significantly higher in group 1 (2.12±0.7) than in group 2 (0.57±0.6, P<0.001). Conclusion: Ocular surface changes, including squamous metaplasia in the bulbar conjunctiva, can be observed in patients with AS.
The aim of this study was to evaluate the tear functions and conjunctival impression cytology (CIC) findings of patients with gout and compare them with healthy controls. Methods: Thirty-four patients with gout (group 1) and 32 age-matched and gender-matched healthy individuals (group 2) were included in this crosssectional study. Schirmer 1 test, tear breakup time (TBUT), Ocular Surface Disease Index (OSDI) score, and CIC grade were evaluated and compared between the groups. Results: There was no significant difference between the groups in gender and age (P¼0.923 and P¼0.078, respectively). The mean of Schirmer 1 test result was significantly lower in group 1 (9.7466.03 mm) than that in group 2 (17.1669.33 mm) (P,0.001). The TBUT was also significantly lower in group 1 (7.0062.09 seconds) than that in group 2 (12.7565.25 seconds) (P,0.001). The OSDI score (20.04612.92) was significantly higher in group 1 than that in group 2 (6.19610.07) (P,0.001). Although 10 patients (29.4%) in group 1 had the CIC grade of 2 to 3, none of the controls had CIC grade 2 to 3. The mean CIC grade in group 1 (1.1560.89) was significantly higher than that in group 2 (0.4760.51) (P,0.001). Conclusions:The results of this study suggest that ocular surface alterations assessed by CIC and tear function abnormalities are more common in patients with gout.
Purpose: This study aims to evaluate the pupillary light reflex measured with dynamic pupillometry in patients who underwent retinal laser photocoagulation due to unilateral retinal vein occlusion (RVO). Methods: A total of 48 patients with unilateral RVO were included in the study. Thirty-four patients had undergone retinal laser photocoagulation while the remaining 14 patients that did not undergo laser treatment were observed for control purposes. Of the laser-treated eyes, 14 eyes (41.2%) had central RVO (CRVO) and 20 eyes (58.8%) had branch RVO (BRVO). Among the 14 patients with RVO without laser treatment, nine eyes (64.3%) had CRVO and five eyes (35.7%) had BRVO. Pupillary light reflexes were assessed with dynamic pupillometry (MonPackOne®; Metrovision, France). The parameters of the eyes with RVO were compared with that of fellow healthy eyes. Results: Mean patient age was 65.8 ± 10.4 years and median time after photocoagulation was 25.5 months. Eyes that received laser photocoagulation had lower pupil contraction amplitude ( p = 0.037), prolonged contraction latency ( p = 0.027), slower contraction velocity ( p = 0.043), and slower dilation velocity ( p < 0.001) compared to healthy fellow eyes. Subgroup analysis revealed that eyes with CRVO had lower contraction amplitude ( p = 0.013) and slower dilation velocity ( p = 0.003), and eyes with BRVO had slower dilation velocity ( p = 0.003). Non-laser-treated eyes with RVO revealed no significant difference in any of the pupillary light reflex parameters compared to fellow eyes. Conclusion: Laser-treated eyes with RVO demonstrated changes in pupillary light reflex parameters including reduced contraction amplitude, prolonged contraction latency, and slower contraction and dilation velocities measured with dynamic pupillometry.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.