A new microrobot manipulation technique with high precision (nano level) positional accuracy to move in a liquid environment with diamagnetic levitation is presented. Untethered manipulation of microrobots by means of externally applied magnetic forces has been emerging as a promising field of research, particularly due to its potential for medical and biological applications. The purpose of the presented method is to eliminate friction force between the surface of the substrate and microrobot. In an effort to achieve high accuracy motion, required magnetic force for the levitation of the microrobot was determined by finite element method (FEM) simulations in COMSOL (version 5.3, COMSOL Inc., Stockholm, Sweden) and verified by experimental results. According to position of the lifter magnet, the levitation height of the microrobot in the liquid was found analytically, and compared with the experimental results head-to-head. The stable working range of the microrobot is between 30 µm to 330 µm, and it was confirmed in both simulations and experimental results. It can follow the given trajectory with high accuracy (<1 µm error avg.) at varied speeds and levitation heights. Due to the nano-level positioning accuracy, desired locomotion can be achieved in pre-specified trajectories (sinusoidal or circular). During its locomotion, phase difference between lifter magnet and carrier magnet has been observed, and relation with drag force effect has been discussed. Without using strong electromagnets or bulky permanent magnets, our manipulation approach can move the microrobot in three dimensions in a liquid environment.
Background The diagnosis of superficial fungal infections is still mostly based on direct microscopic examination with potassium hydroxide solution. However, this method can be time consuming, and its diagnostic accuracy rates vary widely depending on the clinician's experience. Objectives This study presents a deep neural network structure that enables the rapid solutions for these problems and can perform automatic fungi detection in grayscale images without dyes. Methods One hundred sixty microscopic full field photographs containing the fungal element, obtained from patients with onychomycosis, and 297 microscopic full field photographs containing dissolved keratin obtained from normal nails were collected. Smaller patches containing fungi (n = 1835) and keratin (n = 5238) were extracted from these full field images. In order to detect fungus and keratin, VGG16 and InceptionV3 models were developed by the use of these patches. The diagnostic performance of models was compared with 16 dermatologists by using 200 test patches. Results For the VGG16 model, the InceptionV3 model and 16 dermatologists, mean accuracy rates were 88.10 ± 0.8%, 88.78 ± 0.35% and 74.53 ± 8.57%, respectively; mean sensitivity rates were 75.04 ± 2.73%, 74.93 ± 4.52% and 74.81 ± 19.51%, respectively; and mean specificity rates were 92.67 ± 1.17%, 93.78 ± 1.74% and 74.25 ± 18.03%, respectively. The models were statistically superior to dermatologists according to rates of accuracy and specificity but not to sensitivity (p < .0001, p < .005 and p > .05, respectively). Area under curve values of the VGG16 and InceptionV3 models were 0.9339 and 0.9292, respectively. Conclusion Our research demonstrates that it is possible to build an automated system capable of detecting fungi present in microscopic images employing the proposed deep learning models. It has great potential for fungal detection applications based on AI.
This study presents a biomedical device prototype based on small scale hydrodynamic cavitation. The application of small scale hydrodynamic cavitation and its integration to a biomedical device prototype is offered as an important alternative to other techniques, such as ultrasound therapy, and thus constitutes a local, cheap, and energy-efficient solution, for urinary stone therapy and abnormal tissue ablation (e.g., benign prostate hyperplasia (BPH)). The destructive nature of bubbly, cavitating, flows was exploited, and the potential of the prototype was assessed and characterized. Bubbles generated in a small flow restrictive element (micro-orifice) based on hydrodynamic cavitation were utilized for this purpose. The small bubbly, cavitating, flow generator (micro-orifice) was fitted to a small flexible probe, which was actuated with a micromanipulator using fine control. This probe also houses an imaging device for visualization so that the emerging cavitating flow could be locally targeted to the desired spot. In this study, the feasibility of this alternative treatment method and its integration to a device prototype were successfully accomplished.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.