Corrosion of reinforcing steel in reinforced concrete (RC) infrastructure is one of the most detrimental deterioration mechanisms, affecting both safety and serviceability. In the present study, a comprehensive analysis methodology of corrosion damage is adopted. The detrimental effects of corrosion‐induced degradation of material properties on the ultimate capacity of an existing aging RC bridge pier under concentric loading are investigated. A three‐dimensional nonlinear finite element analysis using the commercially available finite element program DIANA is used. The main corrosion‐induced deteriorating factors considered in the present study are: concrete strength degradation within the cover and part of the confined concrete core due to corrosion‐induced cracking, degradation of confinement effects, steel area reduction due to uniform corrosion (in both longitudinal and tie reinforcement), steel ductility degradation due to pitting corrosion, buckling of compressive steel bars due to cross‐section reduction and confinement degradation, and bond strength degradation between steel and concrete induced by concrete cracking/spalling. The methodology is evaluated by comparing the numerical results to those of corroded column tests reported in the literature.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.