Liquid desiccant air-conditioning systems remove directly the latent load from moist air and remove indirectly sensible load of this air by using an indirect evaporative cooling process. The liquid desiccant must subsequently be regeneration once again with a low-grade heat source like solar energy. In this study, calcium chloride solution was used as a desiccant. For the desiccant solution regeneration process, a flat plate solar collector was employed. Different variables, such as the primary airflow rate and desiccant flow rate, were changed during the experiments. The impact of these variables on the performance parameters of the desiccant systems such as moisture removal rate, moisture efficiency, enthalpy efficiency, sensible heat ratio, and the mass transfer coefficient was studied. The obtained results revealed that as the flow rate of primary air increases, the moisture removal rate, sensible heat ratio, and the mass transfer coefficient increase. For example, from 0.006 m/s to 0.0125m/s when the mass airflow rate increased from 0.1 kg/s to 0.18 kg/s.
The desiccant air conditioning system consists of two processes, namely cooling and dehumidification, in which the air temperature and humidity are controlled in order to provide comfortable thermal conditions. A typical system includes a dehumidifier, indirect evaporative cooler, and regenerator. The desiccant is selected depending on its ability to absorb water vapor present in the air. In this study, calcium chloride solution was used as a desiccant for the desiccant solution regeneration process, and a flat plate solar collector was employed. Different variables, such as the primary air flow rate, desiccant flow rate, and the concentration of the desiccant solution, were changed during the experiments. The impact of these variables on the performance parameters of the desiccant system such as moisture removal rate, moisture efficiency, enthalpy efficiency, sensible heat ratio, and the mass transfer coefficient was studied. The obtained results revealed that as the solution concentration and the flow rate of primary air increase, the moisture removal rate, sensible heat ratio, and mass transfer coefficient increase. A particular value of inlet primary air flow rate (0.18Kg/s), an increase in the inlet concentration of calcium chloride solution from 0.85 to 0.95 leads to a rise in moisture removal rate, sensible heat ratio, and mass transfer coefficient of (1.1 _1.65) g/s, (0.18-0.25), and (0.01075-0.0123) m/s respectively. While at a certain inlet concentration of a desiccant solution (0.95), increasing the inlet primary air flow rate from 0.1Kg/s to 0.18Kg/s leads to an increase in the moisture removal rate, sensible heat ratio, and mass transfer coefficient o (0.94-1.26) g/s, (0.24-0.26), and(0.0038 -0.011) m/s respectively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.