An analytical method has been developed to calculate the local energy deposited by alpha particles emitted from radon daughters deposited on the mucus surface in the lung airways. For the particular cases of 218Po (Ra A) and 214Bi (Ra C'), microdose spectra have been evaluated in test spheres of 1 micron diameter which were taken to lie within airways of diameters 18,000, 3,500 and 600 microns. In each case, the contributions of the near and far wall were computed separately. The average microdosimetric parameters yF and yD have also been calculated. For the two smaller airways, yF and yD values were found to be about 110 and 135 keV microns-1 for 218Po and about 87 and 107 keV microns-1 for 214Bi respectively. The corresponding values were about 10% higher for the largest airway.
The Monte Carlo codes EGS4 and MCNP have been compared when calculating radiotherapy depth doses in water. The aims of the work were to study (i) the differences between calculated depth doses in water for a range of monoenergetic photon energies and (ii) the relative efficiency of the two codes for different electron transport energy cut-offs. The depth doses from the two codes agree with each other within the statistical uncertainties of the calculations (1-2%). The relative depth doses also agree with data tabulated in the British Journal of Radiology Supplement 25. A discrepancy in the dose build-up region may by attributed to the different electron transport algorithims used by EGS4 and MCNP. This discrepancy is considerably reduced when the improved electron transport routines are used in the latest (4B) version of MCNP. Timing calculations show that EGS4 is at least 50% faster than MCNP for the geometries used in the simulations.
Simulations with the FLUktuierende KAskade (FLUKA) Monte Carlo code were used to establish the possibility of introducing lead to cover the existing concrete walls of a linear accelerator treatment room maze, in order to reduce the dose of the scattered photons at the maze entrance. In the present work, a pilot study performed at Singleton Hospital in Swansea was used to pioneer the use of lead sheets of various thicknesses to absorb scattered low energy photons in the maze. The dose reduction was considered to be due to the strong effect of the photoelectric interaction in lead resulting in attenuation of the back-scattered photons. Calculations using FLUKA with mono-energetic photons were used to represent the main components of the x-ray spectrum up to 10 MV. Mono-energetic photons were used to enable the study of the behaviour of each energy component from the associated interaction processes. The results showed that adding lead of 1 to 4 mm thickness to the walls and floor of the maze reduced the dose at the maze entrance by up to 80%. Subsequent scatter dose measurements performed at the maze entrance of an existing treatment room with lead sheet of 1.3 mm thickness added to the maze walls and floor supported the results from the simulations. The dose reduction at the maze entrance with the lead in place was up to 50%. The variation between simulation and measurement was attributed to the fact that insufficient lead was available to completely cover the maze walls and floor. This novel proposal of partly, or entirely, covering the maze walls with lead a few millimetres in thickness has implications for the design of linear accelerator treatment rooms since it has the potential to provide savings, in terms of space and costs, when an existing maze requires upgrading in an environment where space is limited and the maze length cannot be extended sufficiently to reduce the dose.
The determination of x-ray spectra near the maze entrance of linear accelerator (LINAC) rooms is challenging due to the pulsed nature of the LINAC source. Mathematical methods to account for pulse pileup have been examined. These methods utilize the highly periodic pulsing structure of the LINAC, differing from the effects of high-intensity radioactive sources. Methods: Sodium iodide (NaI) and plastic scintillation detectors were used to determine the energy spectra at different points near the maze entrance of a medical LINAC. Monte Carlo calculations of the energy distribution of scattered photons were used to simulate the energy spectrum at the maze entrance. The proposed algorithm uses the Monte Carlo code, FLUKA, to calculate a response function for both detectors. To determine the effects of the pileup in the spectra, the Poisson distribution was used, employing the average number of photons per pulse (l) interacting with the detector. The quantity, l, was obtained from the ratio of the number of events detected to the number of pulses delivered. The energy spectra at various distances from the maze entrance were measured using NaI and plastic scintillation detectors. From these measurements, the values of µ were calculated, and the pileup probability was determined. The FLUKA Monte Carlo code was used to calculate the spectrum at the maze entrance and the response matrices of the NaI and plastic scintillation detectors. The algorithm based on the Poisson distribution was applied to calculate the spectrum. Results: The agreement between the calculated and measured spectra was within the first standard deviation of the variance expected in µ. This agreement confirms that photons at the maze entrance have energies between 30 and 240 keV for a maze with three turns, with an average energy of around 85 keV. After pileup correction, the range of the pulse height distribution with the plastic scintillation detector, which has a low atomic number, was decreased (0 to 140 keV). In contrast, the range of the pulse height distribution with the NaI scintillation detector was closer to the photon spectrum (0 to 240 keV). Conclusions: The corrected spectrum demonstrates that using a FLUKA Monte Carlo code and an algorithm based on the Poisson distribution are effective methods in removing the distortion due to the pileup in LINAC spectra when measuring with NaI and plastic scintillation detectors. The agreement between the corrected and measured spectra indicates that Monte Carlo modeling can accurately determine the spectrum of a LINAC machine at the maze entrance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.