The influence of combined supply voltage parameters (bias voltage and voltage pulse amplitude) on efficiency of ozone synthesis in the negative pulsed corona discharge in oxygen was obtained. Pulse overvoltage led to intensification of discharge processes. Bias voltage applied during the discharge channel relaxation essentially increased the efficiency of ozone synthesis. It was established that the “optimal” bias voltage which provides maximum ozone generation doesn’t depend on voltage pulse amplitude, but depends on input oxygen concentration and generated ozone concentration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.