The easy detection of fouling in duct systems is a persistent problem and remains a relevant demandfor the chemical, oil, food and pharmaceutical industries. This work presents preliminary research results of vibrational hammer excitation for easy to use external non-invasive, non-destructive fouling detection in pipelines and other large scale duct systems. The main goal is the detection of inner pipe layer formation, and thickness estimation of the adsorbed material. Data were taken from the vibration amplitude variation in presence of an inner pipe fouling layer using acoustic accelerometer detection, combined with FE (Finite Elements). The experimental set-up, achievable sensitivity and limitations ofthe method are outlined.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.