Ferroresonance is an interaction phenomenon between non-linear inductance and capacitance that initiates abnormal waveform of current and voltage. This phenomenon is very sensitive to system parameter and initial condition. In this paper, ferroresonance initiation involved a basic circuit of series ferroresonance with variation of source voltage magnitude on a single phase low voltage transformer. The scheme of experiment was based on the case of transformer energizing. The trends of current and voltage waveform on the primary windings were investigated and transformed by using Fast Fourier Transform (FFT). The harmonics spectrum was then employed to identify the feroresonance mode and calculate the Total Harmonics Distortion (THD) of current and voltage. The experimental results showed that the higher source voltage magnitude caused the ferroresonance responses to be seen more clearly. It was indicated by the more distorted waveform, the higher odd harmonics frequency amplitude especially for 150 Hz, and the greater THD. Based on the harmonics spectrum and wave period, the ferroresonance responses were identified as fundamental mode. The effects of initial conditions, such as residual flux of transformer and capacitor charge, were also seen on the distorted wave peak during transient condition. In addition, the difference of waveform between normal and ferroresonance condition could be more easily observed on the voltage than the current. The waveforms of current and voltage during experiment had been verified by using simulation.
Contaminants in transformer oil insulation can float when meeting several conditions. Then, the presence of floating contaminants affects the electrical characteristics of oil insulation. Therefore, the pre-breakdown (corona) and breakdown characteristics due to metallic floating particles in transformer oil insulation would be investigated. This test used DC high voltage stress. A 56 Ω resistor was connected to the oscilloscope to detect the corona currents. The camera was used to capture the images of corona light emission. In addition, the electric field between the electrode and particles was simulated. The variables were the particle size, including its shape, and the distance between the particles and the grounded electrode. The experimental results show that the average value of corona inception and breakdown was inversely proportional to the size of floating particles. The peak value of corona current was directly proportional to the particle size. The lowest breakdown voltage was found when the particle was close to the electrode, but they were not in contact.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.