Purpose: To evaluate the changes in intraocular pressure (IOP), central corneal thickness (CCT), axial length, and ocular surface in patients with end-stage renal failure after singlesession hemodialysis treatment and to examine the correlation of these findings with systemic hemodynamic parameters. Patients and Methods: A total of 112 eyes of 112 patients enrolled in a hemodialysis treatment program for three times a week (approximately four hours per session) for at least three months in our hospital between December 2019 and March 2020 were included in the study. Approximately 30 minutes before and after hemodialysis, the best-corrected visual acuity measurement, slit-lamp examination, IOP measurement, and dilated fundus examination with the Goldmann applanation tonometer were performed in all patients. The axial length measurement was undertaken by ultrasonic biometry, and the CCT measurement by ultrasonic pachymetry. The ocular surface evaluation was performed based on the tear breakup time (BUT), basal secretion time (BST) and keratoepitheliopathy score. Blood pressure, serum osmolarity, and body weight were measured before and after hemodialysis. Results: The mean IOP decreased from 12.2 ± 3.5 to 10.8 ± 2.2 mmHg, and the mean decrease was 1.4 ± 2 mmHg, indicating statistical significance (p<0.001). The mean CCT dropped from 502 ± 41.2 to 494.1 ± 35.4 μm, and the mean decrease was 8.1 ± 7.7 μm, which also indicated a statistically significant change (p<0.001). The mean axial length was reduced from 23.1 ± 0.8 to 22.9 ± 0.8 mm. The reduction in the axial length was significant with an average value of 0.26 ± 0.15 mm (p<0.001). When the ocular surface changes were examined, BUT decreased from 7.4 ± 3.1 to 6.3 ± 2.5 s, BST from 8.6 ± 1.7 to 6.6 ± 1.3 mm, and the keratoepitheliopathy score increased from 0.36 ± 0.61 to 1.59 ± 0.93, and all these changes were statistically significant (p<0.001). There was a significant correlation between the axial length change and the IOP change (r=0.202, p=0.03). A significant correlation was also observed between BST and plasma colloid osmotic pressure (r=−0.268, p=0.004). In addition, there was a strong correlation between serum osmolarity and the keratoepitheliopathy score (r=−0.437, p<0.001). Conclusion: Hemodialysis causes significant changes in IOP, CCT, axial length, and ocular surface. These changes should be considered in the ophthalmological examination of patients after the hemodialysis session.