In general, dietary antigens are tolerated by the gut associated immune system. Impairment of this so-called oral tolerance is a serious health risk. We have previously shown that activation of the ligand-dependent transcription factor aryl hydrocarbon receptor (AhR) by the environmental pollutant 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) affects both oral tolerance and food allergy. In this study, we determine whether a common plant-derived, dietary AhR-ligand modulates oral tolerance as well. We therefore fed mice with indole-3-carbinole (I3C), an AhR ligand that is abundant in cruciferous plants. We show that several I3C metabolites were detectable in the serum after feeding, including the high-affinity ligand 3,3´-diindolylmethane (DIM). I3C feeding robustly induced the AhR-target gene CYP4501A1 in the intestine; I3C feeding also induced the aldh1 gene, whose product catalyzes the formation of retinoic acid (RA), an inducer of regulatory T cells. We then measured parameters indicating oral tolerance and severity of peanut-induced food allergy. In contrast to the tolerance-breaking effect of TCDD, feeding mice with chow containing 2 g/kg I3C lowered the serum anti-ovalbumin IgG1 response in an experimental oral tolerance protocol. Moreover, I3C feeding attenuated symptoms of peanut allergy. In conclusion, the dietary compound I3C can positively influence a vital immune function of the gut.
We present the determination of the alkaloid hordenine and its forensic relevance as a qualitative and quantitative marker for beer consumption. A simple, rapid and sensitive ultra-performance liquid chromatography (UPLC)-tandem mass spectrometry (MS/MS) method for the determination of hordenine in human serum samples was developed and validated. The application was tested with serum samples after enzymatic cleavage. After addition of the synthesized internal standard hordenine-D 4, a liquid-liquid extraction with dichloromethane and diethyl ether was performed. Chromatographic separation was conducted with a Waters Acquity® UPLC system with gradient elution on an Agilent Eclipse XDB-C18 column (4.6 mm × 150 mm, 5-μm particle size). For quantification, a Waters Acquity® TQ detector (version SNC 627) with a positive electrospray ionization probe and multiple reaction monitoring mode was used. A flow rate of 0.4 ml/min was applied. The retention time for both the analyte and the internal standard was 3.67 min. Linearity was demonstrated from 0.2 to 16 ng/ml (R(2) > 0.999). The lower limit of quantification was 0.3 ng/ml in serum. Matrix effects and extraction recoveries for low and high concentrations were within acceptable limits of 75-125% and 50%, respectively. To the best of our knowledge there is no corresponding method for the determination of hordenine by UPLC-MS/MS in serum. By our drinking studies we demonstrate that beer consumption leads to detectable hordenine concentrations in serum and observed a linear elimination of total hordenine correlating to blood alcohol concentration, which shows that hordenine can be used as a reliable qualitative and quantitative marker for beer consumption. The validated method was successfully applied to serum from actual forensic cases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.