An open-type pressure recovery system (PRS) for chemical oxygen-iodine laser was designed and fabricated. As a first stage, an active diffuser was used in which the ejecting gas supply was organized through nozzles disposed around the channel periphery. The second stage was a supersonic ejector. Numerical simulation data for the viscous turbulent flow with heat release through the diffuser gas-dynamic channel, and also data obtained by testing the active diffuser in operation on a model facility equipped with a vacuum chamber, are reported. The obtained data were used to develop a full-scale setup with exhaust of laser gas into the atmosphere; this has allowed us to optimize the performance characteristics of the setup and substantially improve its mass-dimensional characteristics. Special attention was paid to parameter matching and synchronization of laser start with the operation of PRS components.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.