Land reclaimed from water bodies or its equivalent (swamp, flood zones and abandon river channel) usually contain certain mechanically unstable geological formations (e.g. peat and clay) which are inimical to the foundation of engineering structures. Concerted effort must therefore be ensured to determine depth to competent layer across the proposed site as against conventional geotechnical test which is a point test.Complementary non invasive geophysical methods must be carried out for any engineering construction so as to ensure stability of building construction and avoid the devastating effects of building collapse rampant of late. Thus, electrical resistivity tomography and induced polarisation methods, constrained by percussion drilling, were used for the present study. The results of the 2-D and 3-D DC resistivity tomography using 64 multi-electrode systems with gradient electrode configuration along five parallel profiles with smallest electrode separation of 4.0m on a total length of 252 m was interpreted using Earth Imager Inversion software. The subsurface was characterised by Peat/Clay sandwich between upper and lower Clayey-sand/Sandy-clay and Sand. The presence of Peat and Clay were correlated to the cause of chronic differential settlements of some engineering structures within the area. The depths to the sand material were observed between 17-47 m. At shallow depths, the sand materials were underlain by mobile clay/peat materials, which correlates with the depth to competent layer (Sand) achieved by percussion drilling in the range of 20-24 m. This lithological sequence in which the near surface sand deposits are underlain by clay/peat saturated with water, gives a sense of instability to the overlaying sandy layer. To buttress this finding, residential and other public buildings surveyed in the entire area are marked with various degrees of distress, ranging from multiple cracks, sinking of building, partial collapse to complete collapse. It should be noted that the depth to the sand layer achieved during the research varied along the respective profiles. Thus application of 2-D resistivity tomography has revealed both the lateral and vertical variation in depth to competent sand layer within the study area as opposed to point information from CPT or Percussion drilling. This provides a useful guide to the site engineers in designing appropriate foundation structure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.