84 years old gentle man with past medical history of hypertension and diabetes presented with sudden onset right sided weakness and aphasia for two hours. Initial neurological assessment revealed National Institute of Health Stroke Scale (NIHSS) 17. Computed tomography (CT) scan demonstrated minimal early ischemic changes along left insular cortex with occlusion of left middle cerebral artery (MCA). Based on clinical and imaging findings, decision was made to perform mechanical thrombectomy procedure. Initially, right common femoral artery approach was utilized. However, due to unfavorable type-III bovine arch, left internal carotid artery could not be engaged via this approach. Subsequently, access was switched to right radial artery. Angiogram revealed small caliber radial artery, with larger caliber ulnar artery. Attempt was made to advance the guide catheter through the radial artery, however significant vasospasm was encountered. Subsequently, ulnar artery was accessed and successful thrombolysis in cerebral infarction (TICI) III left MCA reperfusion was achieved with a single pass of mechanical thrombectomy via this approach. Post procedure neurological examination demonstrated significant clinical improvement. Doppler ultrasound 48 hours after the procedure demonstrated patent flow in radial and ulnar arteries with no evidence of dissection.
Objective: Endovascular treatment of cerebrovascular diseases is often challenging due to small caliber, tortuous distal vessels. Several devices and techniques have evolved to overcome these challenges. Recently, a low profile dual lumen microballoon catheter, specifically designed for distal navigation is employed for neurovascular procedures. Due to its recent advent, scarce data is available on clinical utility and safety of Scepter Mini. The aim of this case series is to report our initial experience with Scepter Mini in the management of various cerebrovascular diseases.Methods: All interventional neurovascular cases performed using Scepter Mini between January 2020 till April 2021 were included. Data regarding patient demographics, procedural details and complications was retrospectively collected from patient's electronic medical record and procedure reports.Results: Total twelve embolization procedures were performed in eleven patients, including six brain arteriovenous malformation, two dural arteriovenous fistula, one vein of Galen malformation and three hyper-vascular glomus tumor embolizations. All procedures were successfully performed with adequate penetration of the embolic agent. Complete embolization was performed in six procedures, while intended partial embolization was performed in the rest of procedures. Scepter Mini was solely used in ten procedures, however in the other two embolization procedures it was used as an additional conjunct tool to complete the intended embolization. No balloon related complication was observed in any procedure.Conclusions: Scepter Mini dual lumen microballoon catheter is safe and feasible for delivery of liquid embolic agents for cerebrovascular embolization procedures.
Background Recently, radial artery access has gained popularity for interventional neurovascular procedures due to patient comfort and fewer complications. However, there are instances where the radial artery approach is not feasible. In such cases, trans-ulnar artery access (TUA) can offer an alternate route. There is limited data regarding neuro-interventional procedures performed via this approach. This study aims to evaluate the feasibility and safety of trans-ulnar approach for a wide range of interventional neurovascular procedures. Materials and methods The data for all patients who underwent ulnar artery access for diagnostic or interventional neuroradiology procedures was retrospectively collected between September 2020 and March 2021. Patient demographics, procedural details, procedure success, and complications were recorded. Results During the study period, 23 patients underwent 24 trans-ulnar approach procedures. The mean age of patients was 50.1 ± 14.2 years. Fourteen diagnostic cerebral angiograms and ten interventional procedures were performed. All procedures were successfully completed via trans-ulnar approach without a switch to alternate access. No major access site complication was observed. Conclusion Ulnar artery access is a safe and feasible option for neurovascular procedures. It can be effectively utilized for diagnostic cerebral angiography and a wide range of interventional procedures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.