Opinions have varied regarding the optimal treatment of an unstable Hangman's fracture. C2 pedicle screw instrumentation is a biomechanically strong fixation which although done through a simple posterior approach, is a technically demanding procedure. This prospective, non-randomized multicentre study included 15 consecutive patients with displaced type II traumatic spondylolisthesis of the axis. There were nine males and six females with a mean age of 37 years at surgery. The cause of injury was a road traffic accident in 11 patients and a fall from height in 4 patients. All patients had a single stage reduction and direct transpedicular screw fixation through the C2 pedicles. During follow-up, clinical evaluation and plain X-rays were performed at each visit; at 6-month follow-up, additional dynamic lateral flexion/extension views and a CT scan were performed. The average follow-up period was 32 months (range 25-56 months). At final follow-up, all patients were asymptomatic and regained a good functional outcome with no limitation of range of motion; all the patients showed solid union with no implant failure. There were no neurological complications. At 6-month follow-up, CT evaluation showed fusion in all patients and an adequate position of 28 screws. Two pedicle screws (6.6%) showed minimal (defined as \2 mm) intrusion; one into the spinal canal and the other into the vertebral foreamen. Transpedicular screw fixation through the C2 pedicles is a safe and effective method in treating type II traumatic spondylolisthesis of the axis resulting in good clinical and radiological outcomes. Adequate reduction was achieved and motion segments were preserved with its use.
We conclude that the option of surgical management must be carefully considered in each case, especially with respect to the potential disadvantages in elderly patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.