Quantitative magnetic resonance imaging (MRI) and spectroscopy (MRS) measurements of energy metabolism (i.e. cerebral metabolic rate of oxygen consumption, CMR O2 ), blood circulation (i.e. cerebral blood flow, CBF, and volume, CBV), and functional MRI (fMRI) signal over a wide range of neuronal activity and pharmacological treatments are used to interpret the neurophysiologic basis of blood oxygenation level dependent (BOLD) image-contrast at 7 T in glutamatergic neurons of rat cerebral cortex. Multi-modal MRI and MRS measurements of CMR O2 , CBF, CBV and BOLD signal (both gradient-echo and spin-echo) are used to interpret the neuroenergetic basis of BOLD image-contrast. Since each parameter that can influence the BOLD image-contrast is measured quantitatively and separately, multi-modal measurements of changes in CMR O2 , CBF, CBV, BOLD fMRI signal allow calibration and validation of the BOLD image-contrast. Good agreement between changes in CMR O2 calculated from BOLD theory and measured by 13 C MRS, reveals that BOLD fMRI signal-changes at 7 T are closely linked with alterations in neuronal glucose oxidation, both for activation and deactivation paradigms. To determine the neurochemical basis of BOLD, pharmacological treatment with lamotrigine, which is a neuronal voltagedependent Na channel blocker and neurotransmitter glutamate release inhibitor, is used in a rat forepaw stimulation model. Attenuation of the functional changes in CBF and BOLD with lamotrigine reveals that the fMRI signal is associated with release of glutamate from neurons, which is consistent with a link between neurotransmitter cycling and energy metabolism. Comparisons of CMR O2 and CBF over a wide dynamic range of neuronal activity provide insight into the regulation of energy metabolism and oxygen delivery in the cerebral cortex. The current results reveal the energetic and physiologic components of the BOLD fMRI signal and indicate the required steps towards mapping neuronal activity quantitatively by fMRI at steady-state. Consequences of these results from rat brain for similar calibrated BOLD fMRI studies in the human brain are discussed.
authors note that Fig. 1 a and c, the third and fourth panels of Fig. 3a, and the first panel of Fig. 3b were printed incorrectly due to a printer's error. The corrected figures and their legends appear below.
The blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) method, which is sensitive to vascular paramagnetic deoxyhemoglobin, is dependent on regional values of cerebral metabolic rate of oxygen utilization (CMR(O2)), blood flow (CBF), and volume (CBV). Induced changes in deoxyhemoglobin function as an endogenous contrast agent, which in turn affects the transverse relaxation rates of tissue water that can be measured by gradient-echo and spin-echo sequences in BOLD fMRI. The purpose here was to define the quantitative relation between BOLD signal change and underlying physiologic parameters. To this end, magnetic resonance imaging and spectroscopy methods were used to measure CBF, CMR(O2), CBV, and relaxation rates (with gradient-echo and spin-echo sequences) at 7 Tesla in rat sensorimotor cortex, where cerebral activity was altered pharmacologically within the autoregulatory range. The changes in tissue transverse relaxation rates were negatively and linearly correlated with changes in CBF, CMR(O2), and CBV. The multiparametric measurements revealed that CBF and CMR(O2) are the dominant physiologic parameters that modulate the BOLD fMRI signal, where the ratios of (deltaCMR(O2)/CMR(O2)/(deltaCBF/ CBF) and (deltaCBV/CBV)/(deltaCBF/CBF) were 0.86 +/- 0.02 and 0.03 +/- 0.02, respectively. The calibrated BOLD signals (spatial resolution of 48 microL) from gradient-echo and spin-echo sequences were used to predict changes in CMR(O2) using measured changes in CBF, CBV, and transverse relaxation rates. The excellent agreement between measured and predicted values for changes in CMR(O2) provides experimental support of the current theory of the BOLD phenomenon. In gradient-echo sequences, BOLD contrast is affected by reversible processes such as static inhomogeneities and slow diffusion, whereas in spin-echo sequences these effects are refocused and are mainly altered by extravascular spin diffusion. This study provides steps by which multiparametric MRI measurements can be used to obtain high-spatial resolution CMR(O2) maps.
It is generally believed that the main olfactory system processes common odors and the accessory olfactory system is specifically for pheromones. The potential for these two systems to respond simultaneously to the same stimuli has not been fully explored due to methodological limitations. Here we examine this phenomenon using high-resolution functional magnetic resonance imaging (fMRI) to reveal simultaneously the responses in the main (MOB) and accessory olfactory bulbs (AOB) to odors and pheromones. Common odorants elicited strong signals in the MOB and weak signals in the AOB. 2-Heptanone, a known mouse pheromone, elicited strong signals in both the MOB and AOB. Urine odor, a complicated mixture of pheromones and odorants, elicited significant signals in limited regions of the MOB and large regions of the AOB. The fMRI results demonstrate that both the main and the accessory olfactory systems may respond to volatile compounds but with different selectivity, suggesting a greater integration of the two olfactory pathways than traditionally believed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.