Background/AimsEndoscopic retrograde cholangiopancreatography (ERCP) is the standard approach for the management of biliary complications in liver transplant patients; however, its safety and efficacy have not been established in this setting. This study was performed to evaluate the safety and long-term efficacy of ERCP in transplant patients.MethodsThe case reports of 1,500 liver transplant patients were reviewed. Orthotopic liver transplantation (OLT) patients were matched 1:2 with non-OLT patients and followed-up for long-term outcome (median, 7.4 years).ResultsOf the 1,500 liver transplant patients, 94 (6.3%) underwent 150 ERCPs after OLT. Anastomotic strictures were present in 45 patients, biliary stones in 24, biliary leaks in 7, papillary stenosis in 2, and primary sclerosing cholangitis in 1. An ERCP success rate of 90.7% was achieved; biliary stenting led to resolution of the bile leak in 7/7 (100%) patients, and biliary stones were removed in 21/24 (87.5%) patients. In addition, 34 of 45 patients with anastomotic stricture underwent endoscopic dilation. We obtained complete resolution in 22/34 (64.7%) patients. OLT patients did not show a higher probability of complications (odds ratio [OR], 1.04), of pancreatitis (OR, 0.80) or of bleeding (OR, 1.34).ConclusionsERCP is safe and effective for the treatment of post-OLT biliary complications, has a low rate of pancreatitis and results in a durable effect.
Background
Wire localization is historically the most common method for guiding excision of non-palpable breast lesions, but there are limitations to the technique. Newer technologies such as magnetic seeds may allow some of these challenges to be overcome. The aim was to compare safety and effectiveness of wire and magnetic seed localization techniques.
Methods
Women undergoing standard wire or magnetic seed localization for non-palpable lesions between August 2018 and August 2020 were recruited prospectively to this IDEAL stage 2a/2b platform cohort study. The primary outcome was effectiveness defined as accurate localization and removal of the index lesion. Secondary endpoints included safety, specimen weight and reoperation rate for positive margins.
Results
Data were accrued from 2300 patients in 35 units; 2116 having unifocal, unilateral breast lesion localization. Identification of the index lesion in magnetic-seed-guided (946 patients) and wire-guided excisions (1170 patients) was 99.8 versus 99.1 per cent (P = 0.048). There was no difference in overall complication rate. For a subset of patients having a single lumpectomy only for lesions less than 50 mm (1746 patients), there was no difference in median closest margin (2 mm versus 2 mm, P = 0.342), re-excision rate (12 versus 13 per cent, P = 0.574) and specimen weight in relation to lesion size (0.15 g/mm2 versus 0.138 g/mm2, P = 0.453).
Conclusion
Magnetic seed localization demonstrated similar safety and effectiveness to those of wire localization. This study has established a robust platform for the comparative evaluation of new localization devices.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.