Background: The Hand Extension Robot Orthosis (HERO) Grip Glove was iteratively designed to meet requests from therapists and persons after a stroke who have severe hand impairment to create a device that extends all five fingers, enhances grip strength and is portable, lightweight, easy to put on, comfortable and affordable. Methods: Eleven persons who have minimal or no active finger extension (Chedoke McMaster Stage of Hand 1-4) post-stroke were recruited to evaluate how well they could perform activities of daily living and finger function assessments with and without wearing the HERO Grip Glove. Results: The 11 participants showed statistically significant improvements (p < 0.01), while wearing the HERO Grip Glove, in the water bottle grasp and manipulation task (increase of 2.3 points, SD 1.2, scored using the Chedoke Hand and Arm Inventory scale from 1 to 7) and in index finger extension (increase of 147 o , SD 44) and range of motion (increase of 145 o , SD 36). The HERO Grip Glove provided 12.7 N (SD 8.9 N) of grip force and 11.0 N (SD 4.8) of pinch force to their affected hands, which enabled those without grip strength to grasp and manipulate blocks, a fork and a water bottle, as well as write with a pen. The participants were 'more or less satisfied' with the HERO Grip Glove as an assistive device (average of 3.3 out of 5 on the Quebec User Evaluation of Satisfaction with Assistive Technology 2.0 Scale). The highest satisfaction scores were given for safety and security (4.6) and ease of use (3.8) and the lowest satisfaction scores were given for ease of donning (2.3), which required under 5 min with assistance. The most common requests were for greater grip strength and a smaller glove size for small hands. Conclusions: The HERO Grip Glove is a safe and effective tool for enabling persons with a stroke that have severe hand impairment to incorporate their affected hand into activities of daily living, which may motivate greater use of the affected upper extremity in daily life to stimulate neuromuscular recovery.
Introduction Wearable robots controlled using electromyography could motivate greater use of the affected upper extremity after stroke and enable bimanual activities of daily living to be completed independently. Methods We have developed a myoelectric untethered robotic glove (My-HERO) that provides five-finger extension and grip assistance. Results The myoelectric controller detected the grip and release intents of the 9 participants after stroke with 84.7% accuracy. While using My-HERO, all 9 participants performed better on the Fugl-Meyer Assessment-Hand (8.4 point increase, scale out of 14, p < 0.01) and the Chedoke Arm and Hand Activity Inventory (8.2 point increase, scale out of 91, p < 0.01). Established criteria for clinically meaningful important differences were surpassed for both the hand function and daily living task assessments. The majority of participants provided satisfaction and usability questionnaire scores above 70%. Seven participants desired to use My-HERO in the clinic and at home during their therapy and daily routines. Conclusions People with hand impairment after stroke value that myoelectric untethered robotic gloves enhance their motion and bimanual task performance and motivate them to use their muscles during engaging activities of daily living. They desire to use these gloves daily to enable greater independence and investigate the effects on neuromuscular recovery.
domain at differentiating adjacent dry eye categories across a range of probability cutoffs with the following Area Under the Curve (AUC) statistics resulting from 2000 stratified bootstrap replicates for each curve: None versus Mild (AUCϭ0.96, CIϭ0.90-0.98), Mild versus Moderate (AUCϭ0.74, CIϭ0.66-0.84) and Moderate versus. Severe (AUCϭ0.82, CIϭ0.74-0.90). CONCLUSIONS: The IDEEL SB domain provides a simple and effective basis for differentiating categories of patient-reported dry eye severity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.