This article explores the feasibility of the use of automated microscopy and image analysis to detect the presence of rare fetal nucleated red blood cells (NRBCs) circulating in maternal blood. The rationales for enrichment and for automated image analysis for "rare-event" detection are reviewed. We also describe the application of automated image analysis to 42 maternal blood samples, using a protocol consisting of one-step enrichment followed by immunocytochemical staining for fetal hemoglobin (HbF) and FISH for X- and Y-chromosomal sequences. Automated image analysis consisted of multimode microscopy and subsequent visual evaluation of image memories containing the selected objects. The FISH results were compared with the results of conventional karyotyping of the chorionic villi. By use of manual screening, 43% of the slides were found to be positive (>=1 NRBC), with a mean number of 11 NRBCs (range 1-40). By automated microscopy, 52% were positive, with on average 17 NRBCs (range 1-111). There was a good correlation between both manual and automated screening, but the NRBC yield from automated image analysis was found to be superior to that from manual screening (P=.0443), particularly when the NRBC count was >15. Seven (64%) of 11 XY fetuses were correctly diagnosed by FISH analysis of automatically detected cells, and all discrepancies were restricted to the lower cell-count range. We believe that automated microscopy and image analysis reduce the screening workload, are more sensitive than manual evaluation, and can be used to detect rare HbF-containing NRBCs in maternal blood.
The authors have developed a cellular analysis platform, based on encoded microcarriers, that enables the multiplexed analysis of a diverse range of cellular assays. At the core of this technology are classes of microcarriers that have unique, identifiable codes that are deciphered using CCD-based imaging and subsequent image analysis. The platform is compatible with a wide variety of cellular imaging-based assays, including calcium flux, reporter gene activation, cytotoxicity, and proliferation. In addition, the platform is compatible with both colorimetric and fluorescent readouts. Notably, this technology has the unique ability to multiplex different cell lines in a single microplate well, enabling scientists to perform assays and data analysis in novel
The use of automated microscopy has reached the maturity necessary for its routine use in the clinical pathology laboratory. In the following study we compared the performance of an automated microscope system (MDS™) with manual method for the detection and analysis of disseminated tumor cells present in bone marrow preparations from breast carcinoma patients. The MDS System detected rare disseminated tumor cells among bone marrow mononuclear cells with higher sensitivity than standard manual microscopy. Automated microscopy also proved to be a method of high reproducibility and precision, the advantage of which was clearly illustrated by problems of variability in manual screening. Accumulated results from two pathologists who had screened 120 clinical slides from breast cancer patients both by manual microscopy and by use of the MDS System revealed only two (3.8%) missed by the automatic procedure, whereas as many as 20 out of 52 positive samples (38%) were missed by manual screening. Cytometry (Comm. Clin. Cytometry) 46:215-221, 2001.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.