Crosstalk is considered as an undesirable phenomenon disturbing the electromechanical behavior of the ultrasonic transducer arrays used in medical imaging applications. Indeed, when one element of a transducer array is excited, it generates parasitic voltages and/or displacement fields on the adjacent passive elements. Consequently, these interactions between elements decrease the array's electroacoustic performance, which affects the obtained image quality. To overcome the crosstalk's problem, several research works propose active cancellation techniques. In this case, the correction voltages are determined by considering the array's elements grounded, contrary to the conventional crosstalk's definition which considers the array elements in Open-Circuit. The novelty of this paper is in one hand the study of the electrical limit conditions' effects on the physical behavior of a piezoelectric transducer array radiating in a fluid medium (water). On the other hand, a displacement method is proposed to evaluate the crosstalk level when the array elements are grounded. The limitations of the proposed method are also discussed. For this purpose, a piezoelectric transducer array is firstly modeled using a Two-dimensional Finite Elements Method (FEM), when the array elements are not grounded (open-circuit). Then, the results are compared to those obtained when the neighboring elements are grounded (as in the case of the crosstalk's active cancellation techniques).Finally, measurements are realized on a fabricated transducer array vibrating in air medium and are successfully compared to the results predicted using FEM.
This work aims to propose an implicit algorithm for solving the magnetoelastic wave propagation in a magnetostrictive actuator. This algorithm is built by combining meshless methods with the Newmark implicit time scheme. The mathematical formulation of vibrations of the actuator is performed by modeling the experimental actuator device by a monodimensional magnetostrictive cylindrical rod attached to an elastic spring, subjected to an axial magnetic field. The formulation of the problem is carried out using the rod model. The study is carried out taking into account mechanical and magnetic effects described by a linear model of strain-stress magnetoelastic relations, whose coefficients depend on the square of the magnetic field, elastic, magnetostrictive, and magnetoelastic characteristics of the elastomagnetic material of which the rod is made. The dynamic equation which describes the magnetoelastic wave propagation in the actuator is obtained by applying the Lagrangian formalism based on the least action principle. The wave propagation is governed by a spatio-temporal partial differential equation whose coefficients are a function of on elastic, magnetostrictive, and magnetic characteristics and implicitly depends on time. The resolution of the dynamic equation is made by adopting two numerical approaches developed by combining the mesh-free collocation methods, the Moving Least Squares (MLS), and the Radial Point Interpolation Method (RPIM) with the Newmark implicit scheme temporal integration. By performing the spatial discretization of the displacement, we obtain a system of linear second-order ordinary differential equations (ODEs), then transform it into a system of first-order ordinary differential equations after integrating Newmark’s implicit time scheme. A comparison of results computed by the proposed numerical approaches RPIM and MLS with experimental data available in the literature is presented. The stability and the solutions qualities of two meshless methods, RPIM and MLS, are also studied. The influence of magnetical and mechanical parameters as well as the coupling coefficients on the performance of the magnetostrictive actuator is also made.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.