Implantable ventricular assist devices (VADs) have proven efficient in advanced heart failure patients as a bridge-to-transplant or destination therapy. However, VAD usage often leads to infection, bleeding, and thrombosis, side effects attributable to the damage to blood cells and plasma proteins. Measuring hemolysis alone does not provide sufficient information to understand total blood damage, and research exploring the impact of currently available pumps on a wider range of blood cell types and plasma proteins such as von Willebrand factor (vWF) is required to further our understanding of safer pump design. The extracorporeal CentriMag (Thoratec Corporation, Pleasanton, CA, USA) has a hemolysis profile within published standards of normalized index of hemolysis levels of less than 0.01 g/100 L at 100 mm Hg but the effect on leukocytes, vWF multimers, and platelets is unknown. Here, the CentriMag was tested using bovine blood (n = 15) under constant hemodynamic conditions in comparison with a static control for total blood cell counts, hemolysis, leukocyte death, vWF multimers, microparticles, platelet activation, and apoptosis. The CentriMag decreased the levels of healthy leukocytes (P < 0.006), induced leukocyte microparticles (P < 10−5), and the level of high molecular weight of vWF multimers was significantly reduced in the CentriMag (P < 10−5) all compared with the static treatment after 6 h in vitro testing. Despite the leukocyte damage, microparticle formation, and cleavage of vWF multimers, these results show that the CentriMag is a hemocompatible pump which could be used as a standard in blood damage assays to inform the design of new implantable blood pumps.
The common complications in heart failure patients with implanted ventricular assist devices (VADs) include hemolysis, thrombosis, and bleeding. These are linked to shear stress-induced trauma to erythrocytes, platelets, and von Willebrand factor (vWF). Novel device designs are being developed to reduce the blood trauma, which will need to undergo in vitro and in vivo preclinical testing in large animal models such as cattle, sheep, and pig. To fully understand the impact of device design and enable translation of preclinical results, it is important to identify any potential species-specific differences in the VAD-associated common complications. Therefore, the purpose of this study was to evaluate the effects of shear stress on cells and proteins in bovine, ovine, and porcine blood compared to human. Blood from different species was subjected to various shear rates (0-8000/s) using a rheometer. It was then analyzed for complete blood counts, hemolysis by the Harboe assay, platelet activation by flow cytometry, vWF structure by immunoblotting, and function by collagen binding activity ELISA (vWF : CBA). Overall, increasing shear rate caused increased total blood trauma in all tested species. This analysis revealed species-specific differences in shear-induced hemolysis, platelet activation, and vWF structure and function. Compared to human blood, porcine blood was the most resilient and showed less hemolysis, similar blood counts, but less platelet activation and less vWF damage in response to shear. Compared to human blood, sheared bovine blood showed less hemolysis, similar blood cell counts, greater platelet activation, and similar degradation of vWF structure, but less impact on its activity in response to shear. The shear-induced effect on ovine blood depended on whether the blood was collected via gravity at the abattoir or by venepuncture from live sheep. Overall, ovine abattoir blood was the least resilient in response to shear and bovine blood was the most similar to human blood. These results lay the foundations for developing blood trauma evaluation standards to enable the extrapolation of in vitro and in vivo animal data to predict safety and biocompatibility of blood-handling medical devices in humans. We advise using ovine venepuncture blood instead of ovine abattoir blood due to the greater overall damage in the latter. We propose using bovine blood for total blood damage in vitro device evaluation but multiple species could be used to create a full understanding of the complication risk profile of new devices. Further, this study highlights that choice of antibody clone for evaluating platelet activation in bovine blood can influence the interpretation of results from different studies.
The therapeutic use of ventricular assist devices (VADs) for end-stage heart failure (HF) patients who are ineligible for transplant has increased steadily in the last decade. In parallel, improvements in VAD design have reduced device size, cost, and device-related complications. These complications include infection and thrombosis which share underpinning contribution from the inflammatory response and remain common risks from VAD implantation. An added and underappreciated difficulty in designing a VAD that supports heart function and aids the repair of damaged myocardium is that different types of HF are accompanied by different inflammatory profiles that can affect the response to the implanted device. Circulating inflammatory markers and changes in leukocyte phenotypes receive much attention as biomarkers for mortality and disease progression. However, they are seldom used to monitor progress during and outcomes from VAD therapy or during the design phase for new devices. Even the partial reversal of heart damage associated with heart failure is a desirable outcome from VAD use. Therefore, improved understanding of the interplay between VADs and the recipient's inflammatory response would potentially increase their uptake, improve patient lives, and fuel research related to other blood-contacting medical devices. Here we provide a review of what is currently known about inflammation in heart failure and how this inflammatory profile is altered in heart failure patients receiving VAD therapy.
Clinical outcomes from ventricular assist devices (VADs) have improved significantly during recent decades, but bleeding episodes remain a common complication of long-term VAD usage. Greater understanding of the effect of the shear stress in the VAD on platelet aggregation, which is influenced by the functional activity of high molecular weight (HMW) von Willebrand factor (vWF), could provide insight into these bleeding complications. However, because VAD shear rates are difficult to assess, there is a need for a model that enables controlled shear rates to first establish the relationship between shear rates and vWF damage. Secondly, if such a dependency exists, then it is relevant to establish a rapid and quantitative assay that can be used routinely for the safety assessment of new VADs in development. Therefore, the purpose of this study was to exert vWF to controlled levels of shear using a rheometer, and flow cytometry was used to investigate the shear-dependent effect on the functional activity of vWF. Human platelet-poor plasma (PPP) was subjected to different shear rate levels ranging from 0 to 8000/s for a period of 6 h using a rheometer. A simple and rapid flow cytometric assay was used to determine platelet aggregation in the presence of ristocetin cofactor as a readout for vWF activity. Platelet aggregates were visualized by confocal microscopy. Multimers of vWF were detected using gel electrophoresis and immunoblotting. The longer PPP was exposed to high shear, the greater the loss of HMW vWF multimers, and the lower the functional activity of vWF for platelet aggregation. Confocal microscopy revealed for the first time that platelet aggregates were smaller and more dispersed in postsheared PPP compared with nonsheared PPP. The loss of HMW vWF in postsheared PPP was demonstrated by immunoblotting. Smaller vWF platelet aggregates formed in response to shear stress might be a cause of bleeding in patients implanted with VADs. The methodological approaches used herein could be useful in the design of safer VADs and other blood handling devices. In particular, we have demonstrated a correlation between the loss of HMW vWF, analyzed by immunoblotting, with platelet aggregation, assessed by flow cytometry. This suggests that flow cytometry could replace conventional immunoblotting as a simple and rapid routine test for HMW vWF loss during in vitro testing of devices.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.