S-ICD reduced lead-related complications but was similar to TV-ICD with regard to non-lead-related complications, including inappropriate therapy. These results support the concept that S-ICD is a safe and effective alternative to TV-ICD in appropriate patients.
Purpose The most common complications of electrophysiology (EP) procedures are related to vascular access. Our study aims to conduct a meta-analysis comparing ultrasound (US)-guided vs. palpation-based technique for femoral venous access in EP procedures. Methods Electronic databases were searched and systematically reviewed for studies comparing femoral vein puncture with/ without US in EP procedures. The primary outcome was the rate of major vascular complications; secondary outcomes were minor vascular complications, inadvertent artery puncture, postprocedural groin pain, and puncture time. Predefined subgroup analysis was conducted separately for patients undergoing pulmonary vein isolation procedure (PVI). A random-effects model was used to derive risk ratios (RR) with 95% confidence interval (CI). Results Nine studies involving 8232 patients met our inclusion criteria. Compared with the standard technique, the use of US reduced major vascular complications (from 2.01 to 0.71%, p < 0.0001). The rate of minor vascular complications (RR = 0.30, 95% CI, 0.14-0.62, p = 0.001) and inadvertent artery puncture were lower with US-guided puncture (RR = 0.31, 95% CI, 0.17-0.58, p = 0.0003). Puncture time was shorter (mean difference = − 92.1 s, 95% CI, − 142.12-− 42.07 s, p = 0.0003) and postprocedural groin pain was less frequent (RR = 0.57, 95% CI, 0.41-0.79, p = 0.0008) in the US group. Subgroup analysis of patients undergoing PVI also showed significant reduction of major vascular complications (RR = 0.27, 95% CI, 0.12-0.64, p = 0.003) and inadvertent artery puncture (RR = 0.35, 95% CI, 0.21-0.59, p < 0.0001). Conclusion Real-time US-guidance of femoral vein puncture in EP procedures is beneficial: it reduces major and minor vascular complications, inadvertent artery puncture, postprocedural groin pain, and puncture time.
Atrio-esophageal fistula is an infrequent but devastating complication of catheter-based ablation of atrial fibrillation (AF). Thermal esophageal injury may be the precursor of atrio-esophageal fistula. Here, we evaluated the role of esophageal temperature monitoring in preventing thermal esophageal injury during pulmonary vein isolation for AF with radiofrequency energy. In this meta-analysis, we searched the PubMed, Cochrane, Scopus, Embase, and Refworks databases for all published studies from January 2004 to June 2016 to evaluate the role of esophageal temperature monitoring. We searched for terms esophageal temperature monitoring, AF, radiofrequency ablation, atrio-esophageal fistula, and thermal esophageal injury. We included studies comparing luminal esophageal temperature (LET) monitoring with no LET monitoring during radiofrequency ablation of AF. We excluded studies in which post-ablation esophagogastroduodenoscopy (EGD) was not performed to identify esophageal thermal injuries. To perform the meta-analysis, we used Review Manager statistical software and a fixed-effects modeling to derive the outcomes. Given significant heterogeneity between the studies, we used meta-regression analysis to adjust for age and sex. We identified 4 non-randomized controlled trials that met our search criteria and included a total of 411 patients (n=235 in the LET monitoring group; n=176 in the no LET monitoring group) in the analysis. There were 21 (8.9%) patients with thermal esophageal injury in the LET monitoring group and 12 (6.8%) in the no LET monitoring group. The pooled odds ratio was 0.66 (0.23-1.89), indicating no statistically significant differences between the 2 groups with regard to esophageal injury. Because of the small sample size and the non-randomized nature of the trials, we observed significant heterogeneity in outcomes among the trials. The role of esophageal temperature monitoring in reducing the risk of esophageal thermal lesions during pulmonary vein isolation for AF has not been established, and more studies including randomized controlled trials are needed to assess its true impact.
Introduction Antiretrovirals have immensely increased the average life expectancy of HIV-positive patients. However, the incidence of QT interval prolongation and other arrhythmias has also increased. Methods Pubmed and Google Scholar were searched for relevant literature published between 1990 and 2019. Results and discussion HIV-positive patients with high viral load, low CD4 count, chronic inflammation, and autonomic neuropathy can develop QT interval prolongation. Another factor prolonging QT interval includes exposure to the HIV transactivator protein, which inhibits hERG K (+) channels controlling IKr K (+) currents in cardiomyocytes. Protease inhibitors inhibiting the CYP3A4 enzyme can also lead to QT interval prolongation. QT interval prolongation can potentially be exacerbated by opioids, antipsychotics, antibiotics, and antifungals, the adjunct medications often used in HIV-positive patients. Hepatic insufficiency in seropositive patients on antiretrovirals may also increase the risk of QT interval prolongation. Conclusion Baseline and follow-up EKG in the susceptible population is suggested.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.